system env temperature threshold yellow

system env temperature threshold yellow
To configure the difference between the yellow and red temperature thresholds that determines the value of
yellow threshold, use the system env temperature threshold yellow command in global configuration
mode. To return to the default value, use the no form of this command.
system env temperature threshold yellow value
no system env temperature threshold yellow value
Syntax Description
value
Command Default
These are the default values
Table 53: Default Values for the Temperature Thresholds
Device
Catalyst 3650
11 You cannot configure the red temperature threshold.
Command Modes
Global configuration
Command History
Release
Cisco IOS XE 3.3SECisco IOS XE 3.3SE
Usage Guidelines
You cannot configure the green and red thresholds but can configure the yellow threshold. Use the system
env temperature threshold yellow value global configuration command to specify the difference between
the yellow and red thresholds and to configure the yellow threshold. For example, if the red threshold is 66
degrees C and you want to configure the yellow threshold as 51 degrees C, set the difference between the
thresholds as 15 by using the system env temperature threshold yellow 15 command. For example, if the
red threshold is 60 degrees C and you want to configure the yellow threshold as 51 degrees C, set the difference
between the thresholds as 15 by using the system env temperature threshold yellow 9 command.
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
970
Specifies the difference between the yellow and red threshold values (in Celsius). The
range is 10 to 25.
Difference between Yellow and
Red
14°C
11
Red
60°C
Modification