These are examples of output from the show env temperature and show env temperature status
commands:
Switch> show env temperature
SYSTEM TEMPERATURE is GREEN
Switch> show env temperature status
SYSTEM Temperature Value: 35.5 Degree Celsius
SYSTEM Temperature State: GREEN
SYSTEM Low Temperature Alert Threshold: 0.0 Degree Celsius
SYSTEM Low Temperature Shutdown Threshold: -20.0 Degree Celsius
SYSTEM High Temperature Alert Threshold: 58.0 Degree Celsius
SYSTEM High Temperature Shutdown Threshold: 80.0 Degree Celsius
POWER SUPPLY 1 Temperature Value: 32.7500 Degree Celsius
POWER SUPPLY 1 Temperature Alert Threshold: 85.0000 Degree Celsius
POWER SUPPLY 1 Temperature Shutdown Threshold: 110.0000 Degree Celsius
FAN TRAY 2: No Temperature Information Provided
Related Commands
Command
system env temperature
threshold alert
alarm-contact
OL-28238-01
Description
Configures the system temperature thresholds.
Configures alarm contacts.
Cisco ME 3800X and ME 3600X Switch Command Reference
show env