Zone Assignment/Alarm Report Codes - ADEMCO VISTA-10SE Programming Manual

Hide thumbs Also See for VISTA-10SE:
Table of Contents

Advertisement

46 REPORT FORMAT
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
For an explanation of these formats, refer to the
SYSTEM
COMMUNICATION
Installation Instructions.
47 SPLIT/DUAL REPORTING
0 = Disable (Backup report only)
TO PRIMARY PHONE NO.
1 = Alarms, Restore, C a n c e l
2 = All except Open/Close, T e s t
3 = Alarms, Restore, C a n c e l
4 = All except Open/Close, Test
5 = A l l ( D u a l R e p o r t i n g )
51 CONFIRMATION OF ARMING DING
0 = disables ding;
1 = enables 1/2 sec ding
2 = enables 1/2 sec ding from RF arming
† Entry of a number other than one specified will give unpredictable results.
These fields are interactive modes. Fill in the required data on the worksheet below (and on next page) and follow
the programming procedure in the installation manual. Zone Types are shown on the next page of this manual.
NOTE: All numbers in brackets [ ] are default settings.
ZONES ON CONTROL:
ZONE
DESCRIPTION
Wired Zone 1
Wired Zone 2
Wired Zone 3
Wired Zone 4
Wired Zone 5
Wired Zone 6
Keypad Panic ( & #, or B)
Keypad Duress
Tamper
Keypad Panic (1 & , or A)
Keypad Panic (3 & #, or C)
[7]
®
REPORTING
section
of
the
[0]
TO SECONDARY PHONE NO.
Other Reports
Open/Close, Test
A l l R e p o r t s
A l l R e p o r t s
A l l R e p o r t s
[0]

56 / 58 ZONE ASSIGNMENT/ALARM REPORT CODES

ZONE
NO.
(Zn)
[01]
0
1
[04]
0
2
[03]
0
3
[03]
0
4
[09]
0
5
[07]
0
6
[06]
0
7
0
8
0
9
[00]
9
5
[00]
9
6
TO PRIMARY PHONE NO.
6 = All except O p e n /Close
7 = All r e p o r t s
8 = All r e p o r t s
9 = All e x c e p t Open/Close
*
Can only be used if Primary reporting is ADEMCO Contact
® .
ID
**
A 10-digit code is sent to the pager consisting of a 4-digit
Subscriber No., a 3-digit Event code, and a 3-digit User (or
Zone No.). See VISTA-10SE Installation Instructions for an
explanation of the paging format.
*** Refer to field 47 in the DATA FIELD DESCRIPTIONS
section of the Installation Instructions.
48 15 SEC DIALER DELAY (BURG)
0 = no delay; 1 = 15 sec delay
UL installations: 0 must be selected .
49 PERIODIC TEST MESSAGE
0 = none; 1 = 24 hours; 2 = weekly; 3 = monthly
(Enter Test Code in field 64.)
UL installations: 1 (24 hours) must be selected.
50 SESCOA/RADIONICS SELECT
0 = Radionics (0 – 9, B – F reporting);
1 = SESCOA (0 – 9 only reporting)
Select 0 for all other formats.
52 ZONE 3 RESPONSE TO OPEN
0 = 400mS nominal; 1 = 10mS nominal
See explanation of headings on next page
ZONE
ALARM RPT CODE
TYPE
(ZT)
[01] [00]
[01] [00]
[01] [00]
[01] [00]
[01] [00]
[01] [00]
[01] [00]
[00] [00]
0
5
[01] [00]
[01] [00]
[01] [00]
– 6 –
TO PAGING NO.* (Secondary)
**Alarms, Open/Close, Troubles
**Alarms, Troubles
**Alarms, Open/Close, Troubles
**Alarms, Open/ C l o s e f o r
u s e r s 5 - 2 5 * * * , T r o u b l e s
[0]
[0]
INPUT
(Hex)
TYPE
(RC)
(In)
HW
HW
HW
HW
HW
HW
[0]
[0]
→ → → →
RF
INPUT
(RT)

Advertisement

Table of Contents
loading

Table of Contents