Alternator Cleaning And Inspection - Jeep 1979 CJ-5 Technical & Service Manual

Table of Contents

Advertisement

CHARGING SYSTEM
1E-11
1. ROTOR
2. F R O N T B E A R I N G R E T A I N E R
3. C O L L A R ( I N N E R )
4. B E A R I N G
5. WASHER
6. F R O N T HOUSING
7. C O L L A R (OUTER)
8. F A N
Ginning and Inspection
9. PULLEY
10. LOCKWASHER
11. PULLEY N U T
12. T E R M I N A L ASSEMBLY
13. RECTIFER BRIDGE
14. REGULATOR
15. BRUSH ASSEMBLY
16. SCREW
Fig. 1E-12 Alternator Components
17. STATOR
18. I N S U L A T I N G WASHER
19. CAPACITOR
20. DIODE T R I O
2 1 . REAR HOUSING
22. THROUGH-BOLT
23. BEARING A N D
SEAL ASSEMBLY
4 3 1 0 5
(1) Clean magnetic poles of rotor by brushing with
oleum spirits.
N O T E : Do not clean with degreasing
solvent.
(2) Inspect slip rings for dirt and roughness. Clean
with solvent. If necessary, clean and finish slip rings
with commutator paper, or 400 grit polishing cloth. Do
not use metal-oxide paper. Spin rotor in lathe or other
support while holding abrasive against rings.
N O T E : When using an abrasive,
support
the rotor
while spinning to clean slip rings evenly. Cleaning slip
rings without support may result in flat spots on slip
nngs, causing brush noise and premature
brush wear.
(3) True rough or out-of-round slip rings in lathe to
0.002 inch maximum indicator reading. Remove only
enough material to make rings smooth and round. Fin-
ish with commutator paper, or 400 grit polishing cloth,
and blow away all dust.
(4) Clean stator by brushing with oleum spirits or
equivalent.