Description
Use Program 12-02 : Automatic Night Service Patterns to define the daily pattern of the Automatic
Program
Mode Switching. Each Mode Group has 10 patterns. These patterns are used in Programs 12-03 and
12-04. The daily pattern consists of 20 timer Settings.
12
Input Data
Item
No.
01
Start Time
02
End Time
03
Operation Mode
Example :
Time Pattern 1
To make the above schedule, it is necessary to set the data as follows:
Time setting 01 :
Time setting 02 :
Time setting 03 :
Time setting 04 :
Time setting 05 :
Time setting 06 :
Time setting 07 :
2-92
Program 12 : Night Mode Setup

12-02 : Automatic Night Service Patterns

Night Mode Service Group Number
Time Pattern Number
Set Time Number
Item
Input Data
0000 ~ 2359
0000 ~ 2359
1 ~ 8 = Night Modes 1 ~
8
0 :0 0
9 :0 0
M o d e 3
M o d e 1
(m id n ig h t)
(d a y)
00 : 00 to 09 : 00
09 : 00 to 12 : 00
12 : 00 to 13 : 00
13 : 00 to 17 : 00
17 : 00 to 18 : 00
18 : 00 to 22 : 00
22 : 00 to 00 : 00
Per Night Service Group, Per Time Pat-
tern, assign a starting time pattern. The
first time pattern must start at 00:00 (mid-
night).
Per Night Service Group, Per Time Pat-
tern, assign an ending time pattern. Each
used time pattern must have a starting and
ending time assigned.
1 2 :0 0
1 3 :0 0
1 7 :0 0
M o d e 4
M o d e 1
M o d e 4
(re st)
(d a y)
(re st)
Mode 3 (midnight)
Mode 1 (day)
Mode 4 (rest)
Mode 1 (day)
Mode 4 (rest)
Mode 2 (night)
Mode 3 (midnight)
01 ~ 04
01 ~ 10
01 ~ 20
Description
1 8 :0 0
2 2 :0 0
0 :0 0
M o d e 2
M o d e 3
(n ig h t)
(m id n ig h t)
Program 12 : Night Mode Setup
ISSUE 4.0
Default
Refer below
Refer below
Refer below