SL1100
Program 80 : Basic Hardware Setup for System
Level:
IN
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is
Program
defined by the combination of 32 Basic Tones.
80
Input Data
Item
No.
01
Repeat Count
Item
No.
02
Basic Tone Number
03
Duration Count
04
Gain Level (dB)
Basic Tone No.
2-448
Service Tone Number
Item
Unit Number
Item
Table 2-13 Basic Tones
01
02
03
04
05
06
07
08
09
10
11
12
13
14
80-01 : Service Tone Setup
Input Data
0 ~ 255 (0 = Endless)
Input Data
0 ~ 33
(0 = No Tone)
(33 = Default Time Slot)
0 ~ 255 (0, 100 ~ 25500 ms)
0 ~ 63 (- 15.5 ~ + 15.5)
Frequency (Hz)
400
520
580
660
700
800
880
1050
350 / 440
440 / 480
480 / 620
440
-- Reserve --
520 / 650
Program 80 : Basic Hardware Setup for System
ISSUE 4.0
01 ~ 64
Default
Refer below
1 ~ 8
Default
Refer below
Refer below
Refer below
Level (dB)
- 13
- 13
- 13
- 13
- 13
- 13
- 13
- 13
- 16 / - 16
- 16 / - 16
- 21 / - 21
-16
-
-19 / -13