NEC SL1100 Programming Manual page 561

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 4.0
Alarm
Re-
Type
Name
No.
port
6
0
0
Blocking
8
1
0
RAM
Backup
Battery
Error
10
0
0
ISDN Link
Error
11
0
0
CTI Link
Error
14
0
0
LAN Link
Error
15
0
0
Network
Keep
Alive
(V1.5
Added)
Programming Manual
Content of
Cause
Alarm
The link of ter-
1.
Terminal
minals connec-
Breakdown.
ted with the ESI
2.
Faulty wiring
package came
and wiring ter-
off.
mination.
3.
External
noise.
4.
ESI package
Breakdown.
RAM backup
battery on the
CPU unit is un-
plugged or de-
fective.
Layer1 link of
1.
Check Con-
ISDN lines
nection be-
came off.
tween main
device and
ISDN line.
2.
DSU Break-
down.
3.
The setting of
Program
10-03 does
not corre-
spond to an
actual line.
The link with the
1.
LAN cable de-
CTI server
fective.
came off.
2.
Connected
HUB broken.
3.
The CTI serv-
er doesn't
start normally.
The link with
1.
LAN cable de-
LAN on CPU
fective.
came off.
2.
Connected
HUB broken.
3.
Defective
CPU.
1.
The net-
1.
LAN cable is
work con-
defective.
nection has
2.
Net side trou-
been cut.
ble.
2.
Network
3.
Packet
Keep Alive
blocked by
restoration.
firewall.
3.
Response
4.
Repetition of
notification
IP address.
on network
Keep Alive.
Action
Recovery
Confirm the termi-
The error is
nal connected with
recovered
same ESI. If they
when con-
work normally,
necting or ex-
confirm the break-
changing it.
down or the wiring
for the terminal.
Exchange the ter-
minal that doesn't
work and the work-
ing terminal, and
confirm it's work-
ing. An external
factor of the noise
etc. is thought.
Please reconfirm
wiring and the in-
stallation, etc.
Please inquire of
the manufacturer
when the problem
occurs after it con-
firms it.
Check the battery
The error is
connector. If it is
recovered
connected correct-
once the bat-
ly, replace the bat-
tery is re-
tery.
placed.
1.
Confirm the
When the
data of Pro-
connection
gram 10-03.
returns nor-
2.
Confirm wiring
mally, the er-
and the instal-
ror is recov-
lation of DSU.
ered.
3.
Check with the
manufacturer
if the problem
occurs again.
1.
Confirm the
When the
CTI server,
connection
wiring, and the
returns nor-
connection.
mally, the er-
2.
Check the
ror is recov-
manufacturer
ered.
if the problem
occurs again.
Confirm the opera-
When the
tion of LAN con-
connection
nector, LAN cable,
returns nor-
and HUB again.
mally, the er-
ror is recov-
ered.
1.
Confirm that
When the
the defect is
connection
on the Net-
returns nor-
work side.
mally, the er-
2.
Confirm the
ror is recov-
settings of
ered.
HUB and the
router, etc.
SL1100
Alarm
Status
ERR
REC
Program
90
ERR
REC
ERR
REC
ERR
REC
ERR
REC
ERR
REC
WAR
2-541

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents