Mf Tone Receiver Setup - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 4.0
Program 80 : Basic Hardware Setup for System
Level:
MF
Description
Use Program 80-10 : MF Tone Receiver Setup to define the various level and time for MF Tone
Receiver.
Input Data
MF Tone Receiver Type Number
Item
Item
No.
01
Detect Level
02
Start delay time
03
Min. detect level
04
Max. detect level
05
twist level
06
S/N ratio
07
ON detect time
08
OFF detect time
Programming Manual

80-10 : MF Tone Receiver Setup

Input Data
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0 ~ 255 (0.25 step, 0 ms ~ 64 ms)
0 ~ 15
detect level 0 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 1 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 2 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 3 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 4 = - 30 dBm (0) ~ - 45 dBm (15)
detect level 5 = - 35 dBm (0) ~ - 50 dBm (15)
detect level 6 = - 40 dBm (0) ~ - 55 dBm (15)
0 ~ 15
detect level 0 = 0 dBm (0) ~ - 15 dBm (15)
detect level 1 = - 5 dBm (0) ~ - 20 dBm (15)
detect level 2 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 3 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 4 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 5 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 6 = - 30 dBm (0) ~ - 45 dBm (15)
0 ~ 9 (1 dB ~ 10 dB)
0 ~ 4 (- 5 step, 0 dB ~ - 20 dB)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
SL1100
1 = MF Receiver for Extension
2 = MF Receiver for Trunk
3 = -- Reserve --
4 = -- Reserve --
5 = -- Reserve --
Default
Refer below
Refer below
Refer below
Refer below
Refer below
Refer below
Refer below
Refer below
Program
80