Use Program 13-04 : Speed Dialing Number and Name to store Speed Dialing data in the Speed
Dialing areas. This program is also used to define the names assigned to the Speed Dialing numbers.
Input Data
Speed Dialing Bin Number
Item
Item
No.
01
Speed Dialing
Data
02
Name
03
Transfer Mode
Programming Manual
Program 13 : Abbreviated Dialing

13-04 : Speed Dialing Number and Name

Input Data
*
1 ~ 9, 0,
, #, Pause
Per speed dial bin (000 ~ 999) as-
(Press line key 1),
sign the telephone number that is to
Recall/Flash (Press line
be called when the bin is accessed.
key 2),
If 13-01-01 is set to (0) do not in-
@ = Code to wait for
clude the trunk access code.
answer supervision in
If 13-01-01 is set to (1) include the
ISDN (Press line key 3)
trunk access code.
(Maximum 36 digits)
Maximum 12 Charac-
Per Speed Dialing bin (000 ~ 999)
ters (Use dial pad to
assign a name to be used when
enter name)
searching through the directory.
If a name is not assigned for a
speed dial bin the speed dial entry
will not be listed in the directory.
0 = Not Used (Calls will
not be routed based off
a users caller ID.)
1 = Internal Dial (Calls
will be routed to an in-
ternal number specified
in PRG 13-04-04.)
2 = Incoming Ring
Group (Calls will be
routed to a ring group
specified in PRG
13-04-04.)
3 = Remote Monitor
(Used for the security
feature and not Flexible
Caller ID routing.)
000 ~ 999
Description
Each time when this setting is
changed Program 13-04-04 will
be reset. (V1.5 Added)
SL1100
Default
Related
Program
No Setting
No Setting
0
2-103
Program
13

Hide quick links: