NEC SL1100 Programming Manual page 562

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Alarm
Type
No.
17
18
30
Program
90
31
32
50
51
54
55
2-542
Re-
Content of
Name
port
Alarm
1
0
Denial of
The system re-
service
ceived illegal
packet.
1
0
Connec-
Digital Station
tion Error
Wiring Error
2
0
SMDR
The temporary
Buffer full
buffer for SMDR
in main device
overflowed, and
a part of output
SMDR data dis-
appeared be-
cause it could
not output
SMDR data.
1
0
Security
Sensor detected
Sensor
abnormality.
detected
1
0
Automatic
Remote watch
Transmis-
function did auto
sion from
dialing.
Remote
Surveil-
lance
1
0
System
The system
Start Noti-
started.
fication
0
0
System
CPU Upgrade is
Data
performed or
change
Programming
change is made.
2
0
License
A new TCP/IP
Manage-
terminal and the
ment Ta-
DSP board were
ble Full
not able to be
added to the ap-
plication license
management ta-
ble.
• The license
management
table is regis-
tering full.
2
0
Regular
The regular
mainte-
maintenance
nance ex-
exchange day
change
has passed.
notifica-
tion.
Cause
Action
Service outage
Confirm whether to
(Dos attack)
find abnormality on
the net side.
The wiring connec-
Check all wiring in
tion between the
between the Multi-
Multiline terminal
line terminal and
and the system
the digital station
has an issue.
card.
1.
Problem of
1.
Confirm
wiring to con-
whether there
nect main de-
is problem in
vice with PC.
wiring to con-
2.
PC Problem.
nect a main
device with
PC.
2.
Execute the
reactivation of
PC.
Sensor detected
Especially, any-
abnormality.
thing need not be
done.
Remote watch
Especially, any-
function did auto
thing need not be
dialing.
done.
The system was
No action needed.
started.
No action needed.
Maximum 512 li-
Please delete li-
cense information
cense information
on the TCP/IP ter-
on an unnecessary
minal is registered,
TCP/IP terminal
and a new terminal
with Program
cannot be regis-
90-44.
tered.
• The regular
Please do the
maintenance ex-
maintenance ex-
change day that
changes of perti-
had been set
nent parts, and set
with Program
the next regular
90-51 exceeded
maintenance ex-
it.
change day with
Program 90-51.
Program 90 : Maintenance Program
ISSUE 4.0
Alarm
Recovery
Status
WAR
MAJ
When the
ERR
output is re-
REC
started, the
error is recov-
ered.
However, the
SMDR data
after the error
occurs is not
recorded.
INF
INF
WAR
The excess
ERR
on the regular
REC
maintenance
exchange
day is can-
celed by
changing
Program
90-51 or
when the
function is in-
validated, the
error is recov-
ered.

Hide quick links:

Advertisement

Table of Contents
loading