Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate
an alarm as Major or Minor. This program also assigns whether or not the alarm information is
reported to the pre-defined destination.
Input Data
Alarm Number
Item
Item
No.
01
Alarm Type
02
Report
Alarm
Re-
Type
Name
No.
port
1
2
0
PKG Initi-
alize Er-
ror.
2
2
0
PKG
Mounting
Error
Programming Manual
Program 90 : Maintenance Program
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0 = Not Report (No autodial)
1 = Report (autodial)

Table 2-18 Description of Alarm

Content of
Alarm
1.
The PKG
1.
PKG not inser-
failed to ini-
ted firmly.
tialize.
2.
PKG was re-
2.
The PKG
moved, but
did not start
not reinserted
normally.
firmly.
3.
Old PKG data
still reported
due to no initi-
alization.
The unit did not
1.
The package
step on a regu-
is not com-
lar procedure
pletely inser-
and it was
ted.
pulled out.
2.
The package
Or, it is not nor-
is out of order.
mally inserted.

90-10 : System Alarm Setup

001 ~ 100
Input Data
Cause
Action
1.
Insert PKG
firmly.
2.
Insert PKG
firmly.
3.
Delete slot in-
formation in
Program
90-05 and in-
sert the PKG
again.
1.
Please insert
the package
firmly.
2.
Please try
again after ini-
tializing the
system data
once when
LED doesn't
blink normally.
3.
Exchange
packages.
SL1100
Default
-
-
Alarm
Recovery
Status
During initiali-
ERR
zation, the
REC
PKG is rec-
ognized.
When unit is
ERR
reconfirmed,
REC
the error is
recovered.