Huawei S1700 Series Web User Manual page 221

Managed series ethernet switches
Hide thumbs Also See for S1700 Series:
Table of Contents

Advertisement

S1700 Managed Series Ethernet Switches
Web User Manual
Table 11-3 Parameters of Information Center
Item
Log State
Buffer Log Level
Trap Log Level
Device
Source IP Interface
Log File Write Delay
Log Server
Table 11-4 Severity Level List
Severity Code
emergencies
alerts
critical
errors
warnings
notifications
informational
debugging
Issue 05 (2012-10-25)
Description
Select Enable to enable system log, and select Disable to disable
system log. The default is Enable.
Buffer Log Level is divided into eight levels, and the information
can be filtered on basis of the levels. The smaller the value level of
system information, the higher the degree of urgency should be.
For the detailed severity level, please refer to 11-4 Severity Level
List.
Trap Log Level is divided into eight levels, and the information can
be filtered on basis of the levels. The smaller the value level of
system information, the higher the degree of urgency should be.
For the detailed severity level, please refer to 11-4 Severity Level
List.
Select a device that sends out the system information.
Select source IP interface of device used to send system
information.
Refers to the interval used to save FLASH. If the interval is 0
(means unlimited time), it should be saved to FLASH manually; if
the interval is 1-65535, the system will be saved to FLASH
automatically according to the entering interval (in minutes).
User can add log server.
Numerical
Description
0
System is unusuable
1
Action must be taken immediately
2
Critical conditions
3
Error conditions
4
Warning conditions
5
Normal but significant condition
6
Informational messages
7
Debug-level messages
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11 Device Management
211

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S1700S1700 seriesS1720V100r007c00

Table of Contents