3
CONVERTER MODE APPLICATION
2. Using an in-house sound system (continued)

1. Configuration

Access the VE-PG3 setting screen, and set the items as shown below.
VE-PG3 (Area A)
Menu Item
Setting Screen
Operating Mode Operating Mode
V/RoIP
IP Line
Extension
Extension connect
Connect
Incoming Call
Port Settings
Transceiver 1 (TRX1) Transceiver Model
EXT Input 1 (EXT1) EXT Control Terminal
EXT Output 1 (EXT1) EXT Control Terminal
Expansion
Priority Control
Setting Item
Item Name
Operating Mode
Operating Mode
EXT I/O Port Mode
EXT I/O Port Mode
SIP Server
IP Phone Number
SIP Server Address
SIP Service Domain
User ID
Password
List of SIP Server Entries Connection Status
Extension
Extension Number
Port Type
Default Call
Destination No.
V/RoIP Incoming
Receive Port
Call Setting
Transceiver Model
Input Connection Port
Valid Timing
Reference Level
Input Analog Gain
Input Digital Gain
Reference Level
Output Analog Gain
Output Digital Gain
Fade-out
Fade-in
Announce Tone
Start Tone
End Tone
Tone Level
Send Connect Success
V/RoIP Control
Tone to Telephone
Notice Tone Volume
Release Timer
No Voice Release Timer 5 (seconds) (Depending on the situation)
Priority Level
Individual Calling
3-6
Value
Converter
Separate
32 (Extension Number set in the VE-PG3 in area B)
192.168.0.3 (IP address set in the VE-PG3 in area B)
192.168.0.3 (Extension Domain set in the VE-PG3 in area B)
32 (Extension Number set in the VE-PG3 in area B)
(Any) (Password set in the VE-PG3 in area B)
Connection successful
301 (Transceiver1)
Transceiver 1 (TRX1)
302
IC-F5060/F6060 (default)
EXT Output
Always-on Connection
(Depending on the external device)
(Depending on the external device)
(Depending on the situation)
(Depending on the situation)
(Depending on the situation)
Priority
(Continued on the next page.)
302 (EXT Output1)
EXT Output 1 (EXT1)
32:302 (EXT1)