Icom VE-PG3 Instruction Manual page 172

Roip gateway
Hide thumbs Also See for VE-PG3:
Table of Contents

Advertisement

5
BRIDGE MODE SETTING SCREEN
9. [Expansion] Menu
M Abnormal Condition Monitoring (continued)
• This is an example.
w PING test .....................
Monitoring
Select "Enable" to send the PING commands to the specified IP address.
When the Ethernet cable is disconnected from the VE-PG3's [LAN] port,
the [WAN] LED blinks Orange, and the error message is displayed on the
"SYSLOG" screen in the "Information" menu.
Control Output
Select "Enable" to output the error detect signal from the B1/B2 terminal
(+/–).
• Select "Relay circuit" in the Control Circuit] item on the [EXT Output](1/2), or
[EXT I/O](1/2) screen.
While the error detect signal sends, the VE-PG3 cannot receive signals from
the external device that is connected to the B1/B2 terminal (+/–).
IP Address:
Enter the destination IP address to send the commands.
Monitor Period:
Set the monitor period between 1 to 4320 minutes.
5-110
[Expansion]–[Abnormal Condition Monitoring]
(Default: Disable)
(Default: Disable)
(Default: 10)