Icom VE-PG3 Instruction Manual page 157

Roip gateway
Hide thumbs Also See for VE-PG3:
Table of Contents

Advertisement

5
BRIDGE MODE SETTING SCREEN
8. [Port Settings] Menu
M EXT Control Terminal (continued)
e Event OFF Time ............
r Control Input Detection ...
t Control Input Pull-up Setting
[EXT2] port
[Port Settings]–[EXT Input 1 (EXT1)/EXT Input 2 (EXT2)]
Select the delay time until the port (B3/B4 terminal (General control input)) is
deactivated.
Range: [0.1], [0.3], [0.5], [1], [1.5], [2], [3] (second)
Select the port input state of B3/B4 terminal (General control input).
When the input port is pulled up:
• Short Circuit (LOW): B3/B4 terminal (General control input) is connected
• Open Circuit (HIGH): B3/B4 terminal (General control input) is open.
When the input port is NOT pulled up:
• Short Circuit (LOW): No voltage is applied to the B3/B4 terminal (General
• Open Circuit (HIGH): A voltage is applied to the B3/B4 terminal (General
Select "Enable" to internally pull up the B3/B4 terminal (General control
input).
A1~A4
A1~A4
B1~B4
B1~B4
C1~C4
C1~C4
A1~A4
A1~A4
A1~A4
A1~A4
B1~B4
B1~B4
C1~C4
C1~C4
A1~A4
A1~A4
VE-PG3 (Rear view)
• See Section 8 for port details.
5-95
(Default: Short Circuit (LOW))
to the GND.
control input).
control input).
B1~B4
B1~B4
C1~C4
C1~C4
B1~B4
B1~B4
C1~C4
C1~C4
(Default: 1)
(Default: Enable)