DVI-D Output Interface (for SP-5B40)

ELECTRIC SHOCK AND FIRE
When using the SG terminal to connect an external device to this product:
Verify that a short-circuit loop is not created when you set up the system.
Connect the SG terminal to remote equipment when the external device is not isolated.
Connect the SG terminal to a known reliable ground connection to reduce the risk of damaging
the circuit.
Failure to follow these instructions will result in death or serious injury.
Product side
Recommendations:
DVI-D Cable manufactured by Pro-face (FP-DV01-50 <5 m>)
Pin No. Signal Name
1
TMDS DATA 2-
2
TMDS DATA 2+
3
TMDS DATA 2 SHIELD
4
NC
5
NC
6
DDC Clock
7
DDC Data
8
NC
9
TMDS DATA 1-
10
TMDS DATA 1+
11
TMDS DATA 1 SHIELD
12
NC
13
NC
14
+5V Power
15
GND
16
NC
17
TMDS DATA 0-
18
TMDS DATA 0+
19
TMDS DATA 0 SHIELD
20
NC
21
NC
22
TMDS CLOCK SHIELD
23
TMDS CLOCK+
24
TMDS CLOCK-
Shell
FG
DANGER
Direction
Output
Output
Output
Input/Output
Output
Output
Ground
Output
Output
Output
Output
Functional Ground