Pro-face GP77R Series Connection Manual

Ethernet connection between hitachi industrial equipment system plcs and gp units
Hide thumbs Also See for GP77R Series:

Advertisement

Device/PLC Connection
Manuals
About the Device/PLC Connection Manuals
Prior to reading these manuals and setting up your device, be sure to read the
"Important: Prior to reading the Device/PLC Connection manual" information. Also,
be sure to download the "Preface for Trademark Rights, List of Units Supported, How
to Read Manuals and Documentation Conventions" PDF file. Furthermore, be sure
to keep all manual-related data in a safe, easy-to-find location.

Advertisement

Table of Contents
loading

Summary of Contents for Pro-face GP77R Series

  • Page 1 Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection manual" information. Also, be sure to download the "Preface for Trademark Rights, List of Units Supported, How to Read Manuals and Documentation Conventions"...
  • Page 2: System Structure For Ethernet Connection

    This section explains the system structures for the Ethernet connection between Hitachi Industrial Equipment System PLCs and GP units. HIDIC H Series LinkI/F Cables Unit Ethernet Unit H4010(CPU3-40H) LAN-ETH Ethernet cable Pro-face Ethernet H2002(CPU2-20H) (compatible I/F Unit H1002(CPU2-07H) with the GP070-ET41 H702(CPU2-20H) IEEE802.3) GP377-MLTE11...
  • Page 3 Hitachi Industrial Equipment System - Ethernet Optional Built-in Series Name Product Name Ethernet I/F Unit Ethernet Port GP77R Series GP-377R Series GP-377RT *1 *2 GP-477R Series GP-477RE GP-577R Series GP-577RS GP-577RT GP2000 Series GP-2300 Series GP-2300L GP-2300S GP-2300T GP-2400 Series...
  • Page 4 Hitachi Industrial Equipment System - Ethernet Connection Structure <1 : n connection> UDPConnection: Up to 32 units TCPConnection: Up to 3 units(GP2000/GLC2000 series) Up to 2 units (GP77R series) GP Series HIDIC H Series 10BASE-T Cable Optional Units •EGP070-ET41 •EGP377-MLTE11 •EGP377-MLTE41...
  • Page 5 <Multiple CPU Links> PLCs on Ethernet Network: UDP Connection: Up to 32 units TCP Connection: Up to 3 units (GP2000/GLC2000 series) Up to 2 units (GP77R series) PLC using CPU Link: Up to 64 units HIDIC H Series HIDIC H Series...
  • Page 6: Supported Devices

    Hitachi Industrial Equipment System - Ethernet 7.8.2 Supported Devices The following list shows the range of devices supported by the GP. HIDIC H Series Setup System Area here. Double Word Device Bit Address Word Address Other Address External Input X0000 ~ X05A95 WX0000 ~ WX05A7 DX0000 ~ DX05A6 External Output...
  • Page 7 Hitachi Industrial Equipment System - Ethernet Web Controller Device Bit Address Word Address Double Word Address Remarks External Input X000 to X005 External Output Y000 to Y005 DY10 Internal Output R000 to R7BF Special Internal Output R7C0 to R7FF Internal Output M0000 to M3FFF WM0000 to WM3FF DM000 to DM3FE...
  • Page 8 Hitachi Industrial Equipment System - Ethernet HIDIC H Series Ethernet Protocol Limitations When conecting your GP/GLC unit using the HIDIC H Ethernet Protocol to an HIDIC H Series unit or a Web Controller, the following limitations apply. Device Address and Node Number Limitations When a device address’s size is larger than 1024 (1K) or a different Node Number set, the number of available device addresses will vary.
  • Page 9 Hitachi Industrial Equipment System - Ethernet PLC Device Block Write Restrictions The GP unit processes data internally by separating data into blocks of 1024 words. Therefore, when a Block Write is requested that uses 41 or more words and will exceed the 1024 word limit, the following features cannot be used.
  • Page 10 Hitachi Industrial Equipment System - Ethernet When setting up Parts or Tags from GP-PRO/PBIII for Windows Before setting up Parts or Tags, Network Information settings must be entered. Network Information Setting can be set from the [GP SYSTEM SETTING]- >[MODE SETTING]->[Network Information] screen. This manual, 7.7.3 Environment Setup Specifying the PLC’s Node Address when setting parts or tags allows the specified PLC’s Device to be read out.
  • Page 11 Hitachi Industrial Equipment System - Ethernet <When CPU Link is used> Set the [Using CPU Link] check box to ON (checked mark). When using the CPU Link, Loop No. and Unit No. are included in the address. Ex.)Using Node Address is 1, Loop No. is 2 and Unit No. is 3 1.
  • Page 12: Environment Setup

    Hitachi Industrial Equipment System - Ethernet 7.8.3 Environment Setup GP Settings The following screens show the GP/GLC's communication settings, which are re- quired for communication via an Ethernet Network: SET UP OPERATION SURROUNDINGS MENU <GP-477R/GP-577R/GP-2400/GP-2500/GP-2501/GP-2600/GLC2400/GLC2600 Series> <GP-377R/GP-2300/GLC2300 Series> GP-PRO/PBIII for Windows Device/PLC Connection Manual...
  • Page 13 Hitachi Industrial Equipment System - Ethernet • SET UP OPERATION SURROUNDINGS <GP-477R/GP-577R/GP-2400/GP-2500/GP-2501/GP-2600/GLC2400/GLC2600 Series> <GP-377R/GP-2300/GLC2300 Series> Be sure the Destination Node No. entered are the same as the PLC’s settings. However, the Destination Node No. settings cannot be changed from the GP’s OFFLINE mode. Be sure to make these settings from the GP-PRO/PBIII for Windows [GP SYSTEM SETUP] ->...
  • Page 14 PLC units’ Port No. to the same value. • PROTOCOL TYPE Select UDP/IP or TCP/IP Communication. When the power is turned ON/ OFF asynchronously , Pro-face recommends UDP/IP Communication. Do not specify duplicate IP addresses. Contact your network manager about assigning IP addresses.
  • Page 15 Hitachi Industrial Equipment System - Ethernet • When using the built-in Ethernet port on a GP2000 Series unit, be sure not to enter duplicate "SRC PORT No." values. • Check the 2-Way driver's "SRC PORT No." Setting via the fol lowing menu: GP OFFLINE mode's Main menu [INITIALIZE] ->...
  • Page 16 Hitachi Industrial Equipment System - Ethernet • SEND WAIT TIME (0 to 255) Wait time can be added when a command is transmitted from the GP. Use the wait time if the traffic on the communications line is heavy. If no wait time is required, enter “0.”...
  • Page 17 Hitachi Industrial Equipment System - Ethernet • DESTINATION NODE INFORMATION <GP-477R/GP-577R/GP-2400/GP-2500/GP-2501/GP-2600/GLC2400/GLC2600 Series> <GP-377R/GP-2300/GLC2300 Series> • DESTINATION NODE INFORMATION PLC Destination Node Number and IP Address are displayed here. Press [NEXT] button to see the next page. The DESTINATION NODE INFORMATION cannot be set or changed from OFFLINE mode.
  • Page 18: Communication Settings

    Hitachi Industrial Equipment System - Ethernet GP-PRO/PBIII for Windows settings The following items can be entered from GP-PRO/PBIII for Windows [GP SYSTEM SETTINGS] -> [MODE SETTING] area. Menu Sub Menu Item Communication Settings Source IP Address Source IP Port No. Destination IP Address Destination IP Port No.
  • Page 19 Hitachi Industrial Equipment System - Ethernet • Source IP Address (0 to 255) Enter the IP address for the GP at your station. To do this, separate the 32 bits of the IP address into four segments of eight bits each, separate those segments with a dot and then enter them as decimal numbers.
  • Page 20: Mode Settings

    Hitachi Industrial Equipment System - Ethernet • Subnet Mask Enter the subnet mask settings. If no subnet mask is used, enter “0” in all fields. • UDP Retry Count (0 to 255) Designates the number of times the GP re-sends a command when there is no reply from the other port and a timeout occurs.
  • Page 21 Hitachi Industrial Equipment System - Ethernet • NETWORK INFORMATION SETTINGS Click the [Network...] button from[GP System Setting]-[Mode Setting] tab, and the Network Information window will appear. Set and editDestination Node Information here. New Destination Node Information is entered using the following window. •...
  • Page 22: Plc Settings

    Hitachi Industrial Equipment System - Ethernet PLC SETTINGS HIDAC H Series GP Settings PLC Settings Source IP Address GP IP Address Source Node GP Port No. Address Target PLC IP Destination IP IP Address Address Address Destination IP Port 3004 to 3007 Logic Port No.
  • Page 23: Error Codes

    Hitachi Industrial Equipment System - Ethernet 7.8.4 Error Codes For information about GP Ethernet Specific Error Codes, refer to the “Protocol Stack Error Codes”. The PLC error codes are displayed by the “ Host Communication Error (02:**)”, and are indicated in the left lower corner of the GP screen. (** indicates the PLC error codes) HIDIC H Series The PLC error codes are sent as separated 2 byte codes.
  • Page 24: Protocol Stack Error Codes

    Protocol Stack Error Codes Protocol Stack Error Codes Protocol Stack Error Codes are displayed on the GP as follows. Host communication error (02:FE:**) ** represents one of the following error codes, from 00 to F0. Error Code Description Notes There is a setup error related to the IP address of your station at initialization.