Specifications

Clock

± 60 seconds per month (deviation at room temperature and power is OFF). Variations in operating
conditions and battery life can cause clock deviations from -380 to +90 seconds per month.
For systems where this level of precision is insufficient, the user should monitor and make
adjustments when required.
Backup clock data uses a supercapacitor (electric double-layer capacitor) for power. When the
voltage from the supercapacitor is low, clock data is lost
The average period for backup is as follows:
Initial: Approximately 100 days
After 5 years: Approximately 30 days (used at ambient temperature of 25 C [77 F])
By connecting the Battery for Memory Backup (Model Number PFXZCBBT1) accessory, you can
set up a backup period of up to 10 years or more.
*1 If clock data is lost, a clock data error message appears when starting up this product. When
this happens, leave this product ON for at least 5 minutes, and then set the clock again. Refer to
your screen editing software manual on how to set up the clock.
NOTE: When using the Open Box, make sure you shut down the unit after changing clock data.