Page 1
Required software/Reference manual An FP3650-T41 unit needs the following software for operation. As FP user manual, provided by PDF media, describes its details, download the manual below and get the further information. Visit our website below and get both software and reference manual.
• For use in Pollution Degree 2 environment. CE Marking Notes The FP3650-T41 is a CE marked product that conforms to EMC directives and Low Voltage directives EN55011 Class A, EN61000-6-2 and EN60950-1 First Edition. * For detailed CE marking information, please contact your local FP distributor.
Part Names A: TFT Color LCD Front View Acts as a display monitor for your host. B: Touch Panel Allows you to switch screens or write data to the host. C: Input Terminal Block Provides the input and ground terminals for a power cable.
Page 4
Dimensions Top View Unit: mm [in] 301[11.85] 58[2.28] 317[12.48] 8[0.31] Side View Front View Dip Switches and Slide Switch The Dip Switches and Slide Switch are located in the bottom of the FP unit. Only the settings when the power supply is turned on is effective to the Dip Switches and the Slide Switch.
DDC Clock Connector....Mini Dsub 15 pin male Connector set screw.. Inch type (4-40) Cable ......RGB cable manufactured by Pro-face. FP-CV02-45 <4.5m> (VGA standard) • If a cable other than the specified RGB cable is used, product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit’s operation.
TMDS CLOCK- Connector....DVI-D 24-pin male Connector set screw.. Inch type (4-40) Cable ......DVI-D cable manufactured by Pro-face. FP-DV01-50 <5 m>, FP-DV01-100 <10 m> • If a cable other than the specified DVI-D cable is used, product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit’s operation.
Page 8
The CD, DTR, and DSR are connected together inside of the FP. Connector....Dsub 9 pin female Connector set screw.. Inch type (4-40) Cable ......SIO cable for FP manufactured by Pro-face. FP61V-IS00-O Concerning Signal Names Signal names used for the serial interface on FP units are designed to match the pin order used on most PC serial interfaces, so that a straight cable can be used to connect the two.
Page 9
Instllation (1) According to the Panel Cut size, make instllation holes on the panel. Unit: mm [in] +0.04 Panel 301.5 [11.87 under 4-R3 Panel thickness 1.6[0.06] to 10[0.39] (2) Check that FP has instllation fastners. Insert the FP from the front. •...
• To avoid the dangers of fire, electric hazards and equipment damage, be sure to use only the specified voltage when operating the FP. • Since there is no power switch on the FP unit, be sure to attach a breaker-type switch to its power cord.
(3) Remove the screws from the two (2) terminals (L,N) and FG (Frame Ground) Terminal, position the Ring Terminals and reattach the screws. (Check each wire to make sure the connections are correct) FG (Frame Ground) Terminal DON’T CONNECT • The torque required to tighten these screws are as follows: Terminal Block: 0.5 to 0.6N•m.
• Between the line and the ground, be sure to use a low noise power supply. If there is still an excessive amount of noise, connect a noise reducing transformer. • Input and Output signal lines must be separated from the power control cables for operational circuits.
Page 13
Item Function Color Settings Adjusts the contrast and the brightness. Adjusts the display position of the screen. Screen Settings (Analog RGB only) Custom Display Adjusts Sharpness and the backlight brightness. System Settings Changes settings such as activating the click sound. All Reset Resets the current OSD value to the default value.
Page 14
• In the OSD, pressing the button applies the set value and enables the setting. The set value won’t be canceled unless the power is turned OFF or the value is reset. If the power is turned OFF without saving the set value, that data will disappear.
Page 15
System Settings Adjustment button Selection of the change item Enables/disables the click sound. With this parameter, Click Tone the sound level can also be adjusted. (Default value: OFF <Click sound disabled>) 720x400 Mode When an input data resolution of 720 x 400 is used in the VGA text mode, set this parameter to ON.