FP3650-T41 Installation Guide
Be sure to read the "Warning/Caution Information" on the attached sheet before using
the product.
FP unit (1)
Installation Guide (1) (this manual)
Installation Gasket (1)(attached to the FP unit)
Installation Brackets (4/set, 1set)
This unit has been carefully packed, with special attention to quality. However, should
you find anything damaged or missing, please contact your local FP distributor
immediately.
Required software/Reference manual
An FP3650-T41 unit needs the following software for operation. As FP user manual,
provided by PDF media, describes its details, download the manual below and get the
further information. Visit our website below and get both software and reference manual.
(URL:http://www.pro-face.com/otasuke/)
• Software
: Mouse Emulation Software
• Manual
: FP-3500T/3600T/3650T series User Manual
Caution
Package Contents
1
Warning/Caution Information (1)
USB Cable Clamp(2)

Advertisement

Table of Contents
loading

Summary of Contents for Pro-face FP3650-T41

  • Page 1 Required software/Reference manual An FP3650-T41 unit needs the following software for operation. As FP user manual, provided by PDF media, describes its details, download the manual below and get the further information. Visit our website below and get both software and reference manual.
  • Page 2: Ul/C-Ul Application Notes

    • For use in Pollution Degree 2 environment. CE Marking Notes The FP3650-T41 is a CE marked product that conforms to EMC directives and Low Voltage directives EN55011 Class A, EN61000-6-2 and EN60950-1 First Edition. * For detailed CE marking information, please contact your local FP distributor.
  • Page 3: Part Names

    Part Names A: TFT Color LCD Front View Acts as a display monitor for your host. B: Touch Panel Allows you to switch screens or write data to the host. C: Input Terminal Block Provides the input and ground terminals for a power cable.
  • Page 4 Dimensions Top View Unit: mm [in] 301[11.85] 58[2.28] 317[12.48] 8[0.31] Side View Front View Dip Switches and Slide Switch The Dip Switches and Slide Switch are located in the bottom of the FP unit. Only the settings when the power supply is turned on is effective to the Dip Switches and the Slide Switch.
  • Page 5: Analog Rgb Interface

    Scanning type : non-interlace •CONTRAST •BRIGHTNESS •H-POSITION •V-POSITION Setting by OSD •H-size •PHASE (On Screen Display) •DIMMER(BACKLIGHT) •SHARPNESS •ALL RESET (DEFAULT) Display Area (FP3650-T41) Screen Resolution H Sync. V Sync. Dot Clock Expansion Display Size (kHz) (Hz) (MHz) (H: Horizontal) Resolution (V: Vertical) 640×400...
  • Page 6: Dvi-D Interface

    DDC Clock Connector....Mini Dsub 15 pin male Connector set screw.. Inch type (4-40) Cable ......RGB cable manufactured by Pro-face. FP-CV02-45 <4.5m> (VGA standard) • If a cable other than the specified RGB cable is used, product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit’s operation.
  • Page 7: Serial Interface

    TMDS CLOCK- Connector....DVI-D 24-pin male Connector set screw.. Inch type (4-40) Cable ......DVI-D cable manufactured by Pro-face. FP-DV01-50 <5 m>, FP-DV01-100 <10 m> • If a cable other than the specified DVI-D cable is used, product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit’s operation.
  • Page 8 The CD, DTR, and DSR are connected together inside of the FP. Connector....Dsub 9 pin female Connector set screw.. Inch type (4-40) Cable ......SIO cable for FP manufactured by Pro-face. FP61V-IS00-O Concerning Signal Names Signal names used for the serial interface on FP units are designed to match the pin order used on most PC serial interfaces, so that a straight cable can be used to connect the two.
  • Page 9 Instllation (1) According to the Panel Cut size, make instllation holes on the panel. Unit: mm [in] +0.04 Panel 301.5 [11.87 under 4-R3 Panel thickness 1.6[0.06] to 10[0.39] (2) Check that FP has instllation fastners. Insert the FP from the front. •...
  • Page 10: Electrical Specification

    • To avoid the dangers of fire, electric hazards and equipment damage, be sure to use only the specified voltage when operating the FP. • Since there is no power switch on the FP unit, be sure to attach a breaker-type switch to its power cord.
  • Page 11: Power Supply Cautions

    (3) Remove the screws from the two (2) terminals (L,N) and FG (Frame Ground) Terminal, position the Ring Terminals and reattach the screws. (Check each wire to make sure the connections are correct) FG (Frame Ground) Terminal DON’T CONNECT • The torque required to tighten these screws are as follows: Terminal Block: 0.5 to 0.6N•m.
  • Page 12: Input/Output Signal Line Cautions

    • Between the line and the ground, be sure to use a low noise power supply. If there is still an excessive amount of noise, connect a noise reducing transformer. • Input and Output signal lines must be separated from the power control cables for operational circuits.
  • Page 13 Item Function Color Settings Adjusts the contrast and the brightness. Adjusts the display position of the screen. Screen Settings (Analog RGB only) Custom Display Adjusts Sharpness and the backlight brightness. System Settings Changes settings such as activating the click sound. All Reset Resets the current OSD value to the default value.
  • Page 14 • In the OSD, pressing the button applies the set value and enables the setting. The set value won’t be canceled unless the power is turned OFF or the value is reset. If the power is turned OFF without saving the set value, that data will disappear.
  • Page 15 System Settings Adjustment button Selection of the change item Enables/disables the click sound. With this parameter, Click Tone the sound level can also be adjusted. (Default value: OFF <Click sound disabled>) 720x400 Mode When an input data resolution of 720 x 400 is used in the VGA text mode, set this parameter to ON.
  • Page 16 8-2-52 Nanko Higashi, Suminoe-ku, Electronics Corporation shall not be held Osaka 559-0031, Japan responsible for any damages or third-party URL:http://www.pro-face.com/ claims for damages or losses resulting from the use of this product. 071257D .FP3650-MT01E-BTH 2006.8 JM/A ©2006 Digital Electronics Corp.

Table of Contents