    Preface Thank you for purchasing Digital’s TFT type color display panel, the ‘FP-3900T series’ (hereafter referred to as the FP unit). Please read this manual completely to insure the correct use and complete understanding of the FP unit’s functions. NOTICE Copying this manual’s contents, either in whole or in part, is prohibited without the express permission of Digital Electronics Corporation, Japan.
  • Page 3: Essential Safety Precautions

    Essential Safety Precautions This manual describes safety instructions for correct use of the FP unit. Please keep this manual close at hand and refer to it when necessary. Safety Icons Throughout this manual, these icons provide essential safety information for FP operation procedures requiring special attention.
  • Page 4 In a situation that a detection function for the backlight burnout has been ineffective, if a burnout of the backlight happened, unlike in an extinction condition of the backlight of FP, the touch panel is still active. If an operator fails to notice that the backlight is burned out and touches the panel, a potentially dangerous machine miss-operation can occur.
  • Page 5 Avoid restricting the FP’s natural ventilation, or storing and using the FP in an environment that will increase the FP’s internal temperature. Do not use the FP in areas where sudden, large changes in temperature may occur. These changes can cause conden- sation to form inside the unit, possibly causing an accident.
  • Page 6: Connecting The Fp To A Pc

    Connecting the FP to a PC The FP-3900TSeries units are designed as a standard SXGA display. Be aware that some types of SXGA equipment may not be within the ranges specified in this document, and, therefore, cannot be connected to the FP. Also, if you change your PC’s SXGA board, there is the possibility that the new board may not be able to be connected to the FP.
  • Page 7: Information Symbols

    Indicates a generic name for the products of . FP-3900T Series Models The FP-3900T Series refers to the following FP model numbers: Power input Series Product Name Model Type Standards type FP-3900T FP3900-T41-U (with front USB) UL/c-UL/CSA Approved, FP-3900T Series CE Marked FP-3900T FP3900-T41 (no front USB)
  • Page 8: Fp-3900T Series Package Contents

    FP Unit (1) Installation Guide (1)(English / Japanese) Installation Guide (This model is FP3900-T41-U ) Installation Gasket Installation Fasteners (12: 4×3 set) (attached to the FP unit) (1) AC Power Connector(atached to the FP unit) (1) USB Cable Clamp (1)
  • Page 9: Main Features

    The FP’s built-in touch panel is standard equipment, allowing touch panel data to be output to a host PC via an RS- 232C cable or USB cable. This is perfect for systems requiring both touch panel operation and data monitoring. • USB-HUB function (Model Type:FP3900-T41-U) The FP-3900T unit has USB-HUB function and can connect USB devices to the front USB connector.
  • Page 10: What Is Ip65F

    Visit our support site below and get both software and reference manual. Digital Electronics Corporation’s support site - Otasuke Pro! http://www.pro-face.com/otasuke/ • Software: Mouse Emulation Software • Manual: FP-3900T series User Manual •...
  • Page 11: Ul/C-Ul/Csa Approval

    Industrial Control Equipment • CSA-C22.2, No.142-M1987 Process Control Equipment Product Model No. UL Registration Model No. FP3900-T41-U 3582701-01 FP3900-T41 <Cautions> • The FP must be used as a built-in component of an end-use product. • This unit should be installed in the front face of a metal panel.
  • Page 12: Ce Marking

    CE Marking The FP-3900T Series is a CE marked product that conforms to EMC directives and Low Voltage directives EN55011 Class A, EN61000-6-2 and EN60950-1 First Edition. *For detailed CE marking information, contact your local FP distributor.
  • Page 13 MEMO...
  • Page 14: Table Of Contents

    Table of Contents Preface......................1 Essential Safety Precautions ................ 2 Connecting the FP to a PC ................5 Information Symbols ..................6 FP-3900T Series Models ................6 FP-3900T Series Package Contents ............. 7 Main Features ....................8 What is IP65f? ....................9 Required Software /Reference Manual ............
  • Page 15 2.6.1 External Dimensions ...................2-16 2.6.2 Dimensions with installation fasteners ..............2-17 2.6.3 Dimensions with Cables..................2-17 2.6.4 Installation Fasteners..................2-18 2.6.5 Panel Cut Dimensions ..................2-19 Chapter 3 Installation and Wiring 3.1 Installation....................... 3-2 3.1.1 Installation Procedures ..................3-2 3.2 Wiring......................3-7 3.2.1 Connecting the Power Cord..................3-7 3.2.2 The USB Cable Clamp..................3-9 3.2.3 Connecting the Power Supply................3-10 3.2.4 Precautions: Grounding ..................
  • Page 16 7.1.1 Cleaning the Display .....................7-2 7.1.2 Installation Gasket Replacement ................7-3 7.2 Periodic Check Points..................7-4 7.3 Backlight Replacement ................... 7-5...
  • Page 17 MEMO...
  • Page 18: Chapter 1 Introduction

    Introduction 1. System Design 2. Optional Equipment This chapter describes the outline of FP Series.
  • Page 19 FP-3900T Series User Manual 1.1 System Design ® The FP can be connected to Pro-face’s PS-2000B or to a Windows compatible PC. FP unit USB I/F For downstream port of FP’s embedded USB-HUB (Type-A connector) *FP3900-T41-U only Peripherals complied with USB2.0/1.1...
  • Page 20 Mouse Emulator software for the FP ® ® ® OS can be Windows NT 4.0 SP6A or higher, Windows 2000 or Windows • Visit our support site below and download the mouse emulation software (UPDD). Digital Electronics Corporation’s support site - Otasuke Pro! http://www.pro-face.com/otasuke/...
  • Page 21 FP-3900T Series User Manual MEMO...
  • Page 22: Chapter 2 Specifications

    Specifications 1. General Specifications 2. Functional Specifications 3. Interface Specifications 4. Cable Diagrams 5. Names and Functions 6. Dimensions This chapter describes the general, functional and interface specifications of the FP as well as its part names and dimensions.
  • Page 23: Electrical Specifications

    FP-3900T Series User Manual 2.1 General Specifications 2.1.1 Electrical specifications Items Specifications Rated Voltage AC100 to 240V Allowable Voltage AC85 to 264V Rated Frequency 50 / 60Hz Rated Frequency Range 40 to 72 Hz Allowable Voltage Drop 1 cycle or less (Voltage drop interval must be 1s or more) AC 100V 1.1A or less (TYP 0.75A) Current Consumption AC 240V 0.7A or less (TYP 0.44A)
  • Page 24: Structural Specifications

    Chapter 2 Specifications 2.1.3 Structural specifications Items Specifications 100 Ω or less, or your country’s applicable standard. Grounding Rating : Equivalent to IP65f (Only not using Front USB) Structure figuration: Bult-in type Installation method: Embedding External Dimensions W460mm [18.11in.] × H390mm [15.35in.] × D77.7mm [3.06in.] Weight Approx.
  • Page 25: Functional Specifications

    FP-3900T Series User Manual 2.2 Functional Specifications 2.2.1 Performance Items Specifications Graphics SXGA (1280 × 1024) Display Unit 19 inch TFT SXGA Type Resistive Film (Analog) Resolution 1024 × 1024 Touch Panel I/F Service Life 35,000,000 times or more Serial Interface (RS-232C) Interface USB Interface (Type-B connector) Analog RGB Interface...
  • Page 26: Interface Specifications

    Chapter 2 Specifications 2.3 Interface Specifications 2.3.1 Analog RGB Interface Input signal type Analog RGB Image signal: analog RGB Input signal Synchronous signal: TTL level, negative polarity or positive polarity characteristic Scanning type: non-interlaced • CONTRAST • BRIGHTNESS • H-POSITION •...
  • Page 27 DDC Clock Connector......:Mini Dsub 15pin male Connector set screw... :Inch type (4-40) Cable........:RGB cable manufactured by Pro-face (FP CV02-45 <4.5m>)(VGA standard) • If a cable other than the specified RGB cable is used, product performance can- not be guaranteed due to the possibility of noise interfering with the FP unit’s...
  • Page 28: Dvi-D Interface

    Chapter 2 Specifications 2.3.2 DVI-D Interface Input signal type DVI-D Setting by OSD • CONTRAST • BRIGHTNESS (On Screen Display) • SHARPNESS • DIMMER (BACKLIGHT) • ALL RESET (DEFAULT) DIsplay Area The number of dots (pixels) displayed are as follows: . Screen Resolution H.Sync.
  • Page 29 TMDS CLOCK- Connector......DVI-D 24-pin male Connector set screw... Inch type (4-40) Cable........DVI-D cable manufactured by Pro-face (FP-DV01-50 <5 m>, FP-DV01-100 <10 m>) • If a cable other than the specified DVI-D cable is used, product performance can- not be guaranteed due to the possibility of noise interfering with the FP unit's operation.
  • Page 30: Serial Interface

    CD, DTR, and DSR are connected together inside of the FP. Connector ......Dsub 9 pin female Connector set screw ...Inch type (4-40) Cable ........SIO cable manufactured by Pro-face (FP61V-IS00-O) • Concerning Signal Names Signal names used for the serial interface on FP units are designed to match the pin order used on most PC serial interfaces, so that a straight cable can be used to connect the two.
  • Page 31: Usb Interface (Up-Stream Port)

    Ground Connector......USB 2.0 / USB 1.1 compliant Connector set screw... Type B connector Cable........USB cable manufactured by Pro-face (FP-US00) • If a cable other than the specified USB cable is used, product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit’s operation.
  • Page 32: Front Usb Interface (Down-Stream Port)(Fp3710-T41-U Model Only)

    Chapter 2 Specifications 2.3.5 Front USB Interface (Down-stream port)(FP3710-T41-U model only) USB Interface Pin Assignments and Signal Names USB 2.0/1.1 compliant • Low (1.5Mbps) Supported speed • Full (12 Mbps) • Hi (480M bps) USB Interface Power supply voltage: 5 VDC ± 5%, Output current: 500mA (max.) Communication distance (Max): 5m Connectable USB: 127...
  • Page 33: Cable Diagrams

    FP-3900T Series User Manual 2.4 Cable Diagrams 2.4.1 RGB Interface Cable Pin Connections (Option cable: VGA standard) Analog R Input RED IN RED VIDEO Output RED VIDEO Analog G Input GRN IN GRN VIDEO Output GRN VIDEO Analog B Input BLU IN BLU VIDEO Output...
  • Page 34: Dvi-D Interface Cable Pin Connections (Option Cable)

    Chapter 2 Specifications 2.4.2 DVI-D Interface Cable Pin Connections (Option cable) TMDS DATA2- Input TMDS DATA2- TMDS DATA2- Input TMDS DATA2- TMDS DATA2+ Input TMDS DATA2+ TMDS DATA2+ Input TMDS DATA2+ TMDS DATA2 SHIELD Input TMDS DATA2 SHIELD TMDS DATA2 SHIELD TMDS DATA2 SHIELD DDC Clock DDC Clock...
  • Page 35: Sio Interface Cable Pin Connections

    FP-3900T Series User Manual 2.4.3 SIO Interface Cable Pin Connections SIO cable Output Input Output Input Input Output Input Output Output Input Input Output Output Input Input Signals and signal names used with the FP and the SIO cable (optional cable) are the same as those used for PCs.
  • Page 36: Names And Functions

    Bottom 4.1.2 Status of Front LED in Operation Modes (page4-3) J: Front USB Connector (Type A)(FP3900-T41-U only) A downstream port for embedded USB-HUB in conformity with USB2.0/1.1 standard, which is used for connecting USB devices. Connect the USB connector (H:USB connector) and Host PC for Front USB connector use.
  • Page 37: Dimensions

    FP-3900T Series User Manual 2.6 Dimensions 2.6.1 External Dimensions Unit: mm [in.] 419[16.50] 100[3.94] [2.95] 77.7 center of 8-M4 12.7 [3.06] [0.14] VESA 460[18.11] [0.50] Effective Screw [0.20] Depth 7 [0.28] center of display area center of unit Side Rear Front 2-16...
  • Page 38: Dimensions With Installation Fasteners

    Chapter 2 Specifications 2.6.2 Dimensions with installation fasteners Unit: mm [in.] 431[16.97] 360[14.17] 419[16.50] 77.7 12.7 [3.06] [0.14] 460[18.11] [0.50] center of display area center of unit Side Side Front 360[14.17] Bottom 2.6.3 Dimensions with Cables Unit: mm [in.] Side Rear Side Bottom...
  • Page 39: Installation Fasteners

    FP-3900T Series User Manual 2.6.4 Installation Fasteners Unit: mm [in.] 16 [0.63] 16.6 [0.65] 31 [1.22] 2-18...
  • Page 40: Panel Cut Dimensions

    Chapter 2 Specifications 2.6.5 Panel Cut Dimensions Unit: mm [in.] +1.0 +0.04 419.5 [16.52 4-R3 [0.12] or less Panel Cut • Panel thickness should be between 1.6mm [0.06in.] and 10mm [0.39in.]. Decide the panel's thickness based on the level of panel strength required. •...
  • Page 41 MEMO...
  • Page 42: Chapter 3 Installation And Wiring

    Installation and Wiring 1. Installation 2. Wiring This chapter explains the installation method and the wiring method for the FP.
  • Page 43: Installation Procedures

    FP-3900T Series User Manual 3.1 Installation 3.1.1 Installation Procedures Follow the steps given below when installing the FP. Check the Installation Gasket’s Seating It is strongly recommended that you use the installation gasket, since it absorbs vibration in addition to repelling water.
  • Page 44: Installation Requirements

    Chapter 3 Installation and Wiring Creating a Panel Cut Create the correct sized opening required to install the FP, using the installation dimensions given. The installation gasket, installation fasteners and attachment screws are all required when installing the FP Decide the panel's thickness based on the level of panel strength required.. 2.6.5 Panel Cut Dimensions (page2-19) •...
  • Page 45 FP-3900T Series User Manual • Be sure that the ambient operating temperature and the surrounding operating humidity are within their designated ranges. (When installing the FP in a cabinet or an enclosure, “Ambient operation temperature” indicates both the panel face and cabinet or enclosure's internal temperature.). Unit: mm [in.] [3.94]...
  • Page 46 Chapter 3 Installation and Wiring Installing the FP Insert the FP into the panel cut, as shown here. Panel Panel Cut Panel Side Insert the installation fasteners into the FP’s insertion slots, at the left, right, top and bottom of the unit. (total: 12 slots) Insertion Slots Left side...
  • Page 47 FP-3900T Series User Manual Insert each of the fasteners as shown below. Be sure to pull the fastener back until it is flush with the rear of the attachment hole. (4) Use a Phillips screw driver to tighten each fastener screw and secure the FP in place. •...
  • Page 48: Wiring

    Chapter 3 Installation and Wiring 3.2 Wiring 3.2.1 Connecting the Power Cord To avoid an electric shock, when connecting the FP’s power cord terminals to the power terminal block, confirm that the FP’s power supply is completely turned OFF, via a breaker, or similar unit.
  • Page 49 FP-3900T Series User Manual Wiring Use the following wiring for FP. Those are Phoenix Contact products. Recommended Drivers SZS 0.6X3.5 (1205053) AI 0.75-10GY(3201288) AI 1-10RD(3200182) Recommended stick end terminal AI 1.5-10BK(3200195) AI 2.5-12BU(3200962) Crimp tool for recommended stick end terminal CRIMPFOX ZA 3 (1201882) Connecting the Power Cord When connecting the AC type power cord, be sure to follow the procedures given below.
  • Page 50: The Usb Cable Clamp

    Chapter 3 Installation and Wiring 3.2.2 The USB Cable Clamp How to use the USB cable clamp USB Cable Clamp Attachment Procedure (1) Connect the USB cable to the connector. (2) Insert the cable clamp into the cable clamp holder as shown in figure 1, and tighten the clamp until the cable is secured in place.
  • Page 51: Connecting The Power Supply

    FP-3900T Series User Manual 3.2.3 Connecting the Power Supply • If the power supply voltage exceeds the FP unit’s spec- Twisted-pair cord ified range, connect a constant voltage transformer. Constant FP Unit Voltage 2 Specifications (page2-1) Transformer • For between the line and ground or between the lines, select a power supply that is low in noise.
  • Page 52: Precautions: Grounding

    Chapter 3 Installation and Wiring 3.2.4 Precautions: Grounding • Connect the FP’s FG terminal to an exclusive ground. (a) Exclusive grounding (BEST) [diagram (a) - Grounding resistance of under 100Ω.] Other FP Unit Equipment • If exclusive grounding is not possible, use a common (b) Common grounding (OK) connection point.
  • Page 53 FP-3900 Series User Manual MEMO 3-12...
  • Page 54: Chapter 4 Setting Up And Adjusting The Fp Unit

    Setting up and Adjusting the FP unit 1. Operation Mode Setup 2. Screen Display Adjustment This chapter describes the settings of the operation mode and the OSD.
  • Page 55: Preset Settings And Adjustments For Dip Switch And Slide Switch

    FP-3900T Series User Manual 4.1 Operation Mode Setup 4.1.1 Preset Settings and Adjustments for Dip Switch and Slide Switch The Dip Switches and Slide Switch are located in the bottom of the FP unit. Loosen the screws of the cover with a Phillips head screwdriver and then remove the cover.
  • Page 56: Status Of Front Led In Operation Modes

    Chapter 4 Setting up and Adjusting the FP unit • Slide Switch is used to switch the data input/output (command control) method on the touch panel between USB and RS-232C. The default setting is RS-232C. 4.1.2 Status of Front LED in Operation Modes Green/ Orange Green...
  • Page 57: Screen Display Adjustment

    FP-3900T Series User Manual 4.2 Screen Display Adjustment 4.2.1 Calibration of OSD Display Position You can operate the FP screen menus via the touch panel, and adjust screen image display to a minute level. The feature is called OSD (On Screen Display). This section describes items and functions that can be set with OSD.
  • Page 58 Chapter 4 Setting up and Adjusting the FP unit • In the OSD, pressing the button applies the set value and enables the setting. The set value won't be canceled unless the power is turned OFF or the value is reset. If the power is turned OFF without saving the set value, that data will disappear.
  • Page 59: Osd Setting Icons

    FP-3900T Series User Manual 4.2.2 OSD Setting Icons Item Function Color Settings Adjusts the contrast and the brightness. Adjusts the display position of the screen. Screen Settings (Analog RGB only) Custom Display Adjusts Sharpness and the backlight brightness. System Settings Changes settings such as activating the click sound.
  • Page 60: Osd Setting Item Details

    Chapter 4 Setting up and Adjusting the FP unit 4.2.3 OSD Setting Item Details Main Menu Color Settings Selection of the change item Adjustment button Contrast Adjusts the contrast. R.Contrast Adjusts the R.contrast. G.Contrast Adjusts the G.contrast. B.Contrast Adjusts the B.contrast. Brightness Adjusts the Brightness.
  • Page 61 FP-3900T Series User Manual System Settings Adjustment button Selection of the change item Click Tone Enables/disables the click sound. With this parameter, the sound level can also be adjusted. (Default value: OFF <Click sound disabled>) When an input data resolution of 720 x 400 is used in the VGA text 720x400 Mode mode, set this parameter to ON.
  • Page 62 Chapter 4 Setting up and Adjusting the FP unit All Reset Resets all the settings and then returns to the top menu. Cancels the setting and then returns to the top menu. Input Source Applies the setting and then returns to the top menu. Cancels the setting and then returns to the top menu.
  • Page 63 FP-3900TSeries User Manual MEMO 4-10...
  • Page 64: Chapter 5 Touch Panel Data

    Touch Panel Data 1. Touch Interface Data This chapter describes the outline of the software to input the touch panel data to the host computer.
  • Page 65 • Visit our support site below and download the mouse-emulation software (UPDD). Digital Electronics Corporation’s support site - Otasuke Pro! http://www.pro-face.com/otasuke/ • For use of USB for sending touch data, the number of the calibration point of mouse emulation software should be 9. (The initial setting is 4.) If you don't change the setting values, the touch position may not be accurate, a little off the point.
  • Page 66 Chapter 5 Touch Panel Data Data Format Touch Panel coordinate data is sent to the host using the following format. All data is in binary format. Header: 1 byte (11h= touched; 10h = released) X coordinate: 2 bytes (0 to 3FFh) Y coordinate: 2 bytes (0 to 3FFh) X coordinate...
  • Page 67 FP-3900T Series User Manual MEMO...
  • Page 68: Chapter 6 Troubleshooting

    Troubleshooting 1. Troubleshooting 2. Error Message...
  • Page 69: Possible Device Problems

    FP-3900T Series User Manual 6.1 Troubleshooting 6.1.1 Possible Device Problems This chapter explains the main method of dealing with the trouble in the use of the FP. • For problems other than problems of the FP, please refer to the manual of each equipment. Possible types of trouble while using this unit are as follows.
  • Page 70: No Display

    Chapter 6 Troubleshooting 6.1.2 No Display When the screen does not display when powering up, or if the screen turns OFF by itself, use the flowchart below to find an appropriate solution. No Screen Display Does the backlight (CCFL) light up? Connect the appropriate voltage.
  • Page 71 FP-3900T Series User Manual Is the PC operating? Start the PC. Are the FP output Set the FP output settings so that they match settings the same as the the PC’s frequency and resolution. PC's frequency and resolution? Connect the RGB cable/DVI-D cable correctly. Is the RGB cable/ DVI-D cable connected 2.4 Cable Diagrams (page2-12)
  • Page 72: Touch Panel Does Not Respond

    Chapter 6 Troubleshooting 6.1.3 Touch Panel Does Not Respond When the touch panel does not react, or its reaction is very slow after it is pressed, follow the flowchart below to find the origin of the problem and the appropriate solution. Touch panel is not working Install the Mouse Emulation Software.
  • Page 73: Error Message

    FP-3900T Series User Manual 6.2 Error Message This section explains the messages that appear when an error has occurred in the FP unit during RUN mode.The problem causing the error message and its related countermeasure are explained in the table below. (Only the latest error message will appear on the FP screen) 6.2.1 Error Message List...
  • Page 74: Chapter 7 Maintenance

    Maintenance 1. Regular Cleaning 2. Periodic Check Points 3. Backlight Replacement This chapter indicates necessary cautions and instruction standards to maintain your FP.
  • Page 75: Cleaning The Display

    FP-3900T Series User Manual 7.1 Regular Cleaning 7.1.1 Cleaning the Display When the display surface or frame become dirty, use a soft cloth moistened with neutral detergent to wipe away any dust or stains. Display Neutral detergent Do not clean the unit with thinner, organic solvents, or strong acids.
  • Page 76: Installation Gasket Replacement

    Chapter 7 Maintenance 7.1.2 Installation Gasket Replacement The installation gasket protects the FP and improves its water resistance. For instructions on installing the FP unit's gasket, refer to the following page. 3 Installation and Wiring (page3-1) • A gasket which has been used for a long period of time may have scratches or dirt on it, and could have lost much of its water resistance.
  • Page 77: Periodic Check Points

    Is the operating atmosphere free of corrosive gasses? Electrical Specifications • Is the Rated Voltage Range appropriate? FP Model Number Rated Voltage Range FP3900-T41-U AC85 ~ 264V FP3900-T41 Rated Items • Are all power cords and cables connected properly? Have any become loose? •...
  • Page 78: Backlight Replacement

    Chapter 7 Maintenance 7.3 Backlight Replacement • FP-3900T series backlights cannot be replaced by customers. When you need to replace the backlight of your FP-3900T, contact your local distributor.
  • Page 79 FP-3900T Series User Manual MEMO...