  • Page 1 Easy! Smooth! Replacement Guidebook GP-3750T > SP-5700TP (Premium Display) + SP-5B00 (Standard Box) The 4 Edition Nov. 2018...
  • Page 2 ->see 1.1 ※ SP-5700TP (Premium Display) and SP-5B00(Standard Box) doesn’t have Video Input I/F and doesn’t support Multimedia features. if using these features on GP-3750T, be aware that you could not replace to SP5000 series. -> see 2.7 ‘Display’ and ‘Box’ of SP5000 series can be separated, so you can freely select a suitable combination of them according to use.
  • Page 3 Contents CHAPTER 1 SPECIFICATION COMPARISON 1.1. S GP-3750T SP-5700TP+SP-5B00 PECIFICATION OF CHAPTER 2 COMPATIBILITY OF HARDWARE 2.1. L OCATIONS OF CONNECTOR 2.2. P OWER SUPPLY 2.3. USB T RANSFER CABLE 2.4. I NTERFACE 2.4.1. S ERIAL NTERFACE 2.4.2. A I/O I...
  • Page 4 CHAPTER 4 COMMUNICATION WITH DEVICE/PLC 4.1. S HAPES AND OMMUNICATION METHOD OF PORTS 4.2. S IGNALS OF PORTS 4.3. C ABLE IAGRAM AT THE TIME OF REPLACEMENT 4.4. M ULTILINK ONNECTION CHAPTER 5 APPENDIX 5.1. C HANGING THE SETTING OF THE EXTERNAL MEDIA TO USE...
  • Page 5 Chapter 1 Specification Comparison 1.1. Specification of GP-3750T and SP-5700TP+SP-5B00 GP-3750T SP-5700TP+SP-5B00 Display Type TFT Color LCD 65,536 colors (without blink)/ 16,777,216 colors Display Colors 16,384 colors (without blink) (with blink) Display Resolution XGA (1,024×768 pixels) Panel Cut Dimensions W383.5×H282.5mm NEW!...
  • Page 6 UP! 1 port Ethernet I/F 2 ports 10BASE-T/100BASE-TX 10BASE-T/100BASE-TX NEW! CF Card I/F ✔ -> see 2.4.5 NEW! SD Card I/F ✔ -> see 2.4.5 UP! SP-5700TP (premium display) Type A 2 ports 1 port (Front) SP-5B00 (Standard box) 2 ports NEW!...
  • Page 7 Chapter 2 Compatibility of Hardware 2.1. Locations of connector Connector locations of GP-3750T and SP-5700TP+SP-5B00 GP-3750T SP-5700TP (Premium display) SP-5B00(Standard box)
  • Page 8 SP-5700TP+SP-5B00 GP-3750T Power Input Terminal Block (AC) / Power Connector (DC) Power Connector (DC) Serial I/F (COM1) Serial I/F (COM2) Ethernet I/F USB I/F (Type A) USB I/F (Type mini B) Storage Card Cover (There’s a SD card I/F for storage under the cover.)
  • Page 9 The SP5000 series has a COM port on the side of box module. The pin array and the shapes of the plug and the socket differ between GP-3750T COM2 port and SP-5B00(Standard box) COM port. The PLC connection cable that used to be connected to GP3000 Series via its COM2 port cannot be used as it is.
  • Page 10 SP5000 series is not equipped with a CF card slot. But a SD card slot and a USB interfaces are installed. In order to use the GP-3750T data saved in the CF card and the functions using the CF card, use a SD card or a USB flash drive instead.
  • Page 11 2.5. Peripheral units and option units 2.5.1. Barcode/ 2D [two-dimensional] code reader connection Like GP3000 series, SP5000 series allows you to connect a barcode reader to its USB interface (Type A) or its serial interface. In replacing GP3000 series with SP5000 series, verify proper operation of the barcode/2D code reader before use.
  • Page 12 2.5.4. Isolation Unit RS-485 isolation unit for GP3000 Series (CA3-ISO485-01) cannot be used for SP-5B00(Standard box). You can use the RS-232C isolation unit (CA3-ISO232-01) for SP-5B00 (Standard box) instead. (The communication method is switched with this unit’s DIP switch.) Note for using RS-232C isolation unit (CA3-ISO232-01) ・...
  • Page 13 2.8. Power Consumption The power consumption of GP3000 series is different from that of SP5000 series. GP-3750T ST-5700TP+SP-5B00 50W or less 40W or less 2.9. About Pro-Server EX Use Pro-Server EX Ver.1.36 or later. For more detail, please refer to the following.
  • Page 14 Chapter 3 Replacement Procedure 3.1. Work Flow Installation Screen Communication Receive screen data from Check the connection Check the compatibility of GP3000 Series. hardware in Chapter 2. between SP5000 series and a PLC in the GP-Pro EX Device/PLC Connection Manual. Change the received data Remove GP3000 Series.
  • Page 15 Please use the same version or later as or than that of the software used during creating screens on GP3000 Series. If you don’t know the version, we recommend you to use the newest version. For the newest version, you can download the transfer tool from our web site called [OtasukePro!] (http://www.pro-face.com/otasuke/download/freesoft/gpproex_transfer.htm). 15 / 29...
  • Page 16 3.3. Receive screen data from GP3000 series You can transfer data to GP3000 Series via; A USB transfer cable (model: CA3-USBCB-01)  A CF card/USB storage device  Ethernet  If you have backed up screen data, this step is unnecessary, skip to the next section [3.4 Change the Display Unit Type].
  • Page 17 (2) Start the Transfer Tool of GP-Pro EX (3) Make sure that the [Device] in the “Transfer Settings Information” is set to [USB]. If not, click the [Transfer Setting] button to open the “Transfer Setting” dialog box. Select [USB] in the Communication Port Settings field and click [OK]. 17 / 29...
  • Page 18 (4) Start GP-Pro EX Transfer Tool and click the [Receive Project] button (5) Click [Receive Project], and the following dialog box will appear. Specify a place to save the received data in and a project file name, and then click [Save] to start transfer.
  • Page 19 (6) The following dialog box appears during transfer and you can check the communication status. (The display unit enters the Transferring mode and communication with the device such as a PLC is terminated.) Display Screen NOTE (1) If you receive the project files that use CF card data such as Recipe Function (CSV data), the following dialog box will appear during transfer.
  • Page 20 (7) When transfer is completed, the status displayed in the dialog box will change from [Transferring] to [Complete Transfer]. Click [Close] to close the dialog box. (8) Close the Transfer Tool. 3.4. Change the Display Unit Type Open the received project file (*.prx) of GP3000 Series on GP-Pro EX and change the display unit type to SP5000 series.
  • Page 21 3.5. Transfer the screen data to SP5000 series Transfer the project file after the display unit type change to SP5000 series. You can transfer data to SP5000 series via; An USB transfer cable (model: CA3-USBCB-01) ・ An USB data transfer cable (model: ZC9USCBMB1) ・...
  • Page 22 (1) Connect your PC and the GP unit of SP5000 series with a USB transfer cable. If the driver of the cable has not been installed on you PC, a dialog box will appear. Please follow the instructions. NOTE ・ The “Hardware Installation” dialog box as shown below may appear during installing the USB driver depending on the security ®...
  • Page 23 (2) Turn on the power of SP5000 series. The “Initial Start Mode” screen will appear on the display unit. After transferring a project file once, this screen will not appear again. (3) On the GP-Pro EX’s State Toolbar, click the [Transfer Project] icon to open the Transfer Tool.
  • Page 24 (4) Make sure that the [Device] in the “Transfer Settings Information” is set to [USB]. If not, click the [Transfer Setting] button to open the “Transfer Setting” dialog box. Select [USB] in the Communication Port Settings field and click [OK]. (5) Click [Send Project] to start transfer.
  • Page 25 3.6. Differences of software Some functions supported by GP3000 Series are not supported by SP5000 series. For details of the details of the supported parts and functions, refer to [Supported Features] of GP-Pro EX Reference Manual (http://www.pro-face.com/otasuke/files/manual/gpproex/new/refer/gpproex.ht 25 / 29...
  • Page 26 SP-5B10(Power box) is required. 4.2. Signals of COM ports At the time of RS-422/485 communication, the signal and the pin array differ between the COM2 port on GP-3750T and the COM2 port on SP-5B00 (Standard box). GP-3750T SP-5B00 (Standard box)
  • Page 27 For RS-232C connection, it can be used for the COM1 on SP-5B00(Standard Box) as it is. When a RS-422/485 device is connected via the COM1 port, if GP-3750T is replaced with SP-5B00(Standard box), it will be connected via the COM2 port of SP-5B00(Standard box).