JRC JMA-9133-SA Instruction Manual page 53

Hide thumbs Also See for JMA-9133-SA:
Table of Contents

Advertisement

JMA-9100 Instruction Manual > 1.GENERAL AND EQUIPMENT COMPOSITION > 1.3 CONFIGURATION
Notes:
1)
The drive motor for the scanner unit is available in AC100-115V
or AC220-240V type for NKE-1139/1130/1125/1129 series. Please
specify the motor type when ordering.
2)
The motor of NKE-2254/2103 can operate under both AC100-115V
and AC220-240V, then need not to specify the motor type.
3)
When using NKE-2254/2103, they need AC/DC Converter NBA-
5135 (Option) in display unit.
4)
The scanner unit except NKE-2103 series can be equipped with a
deicing heater as an option, and '-D' shall be suffixed to the type
name. (e.g. NKE-1139-D, NKE-1125-6D).
When using the ship's mains of AC440V as the radar power
5)
source, a step-down transformer shall be used.
6)
The desktop option is available for display NCD-4990. It has a
separate structure consisting of the following:
Monitor Unit
Radar Process Unit
Operation Unit
In JMA-9123, the following type name of JRC is used for the
7)
flexible wave guide between the scanner unit and the transmitter
receiver unit.
Type of Radar
JMA-9123-7XA/9XA
JMA-9123-7XA/9XA
8)
In JMA-9133, the following type name of JRC is used for the
coaxial cable between the scanner unit and the transmitter
receiver unit.
Type of Radar
JMA-9133-SA
NWZ-170
NDC-1399-9
NCE-5163
Waveguide Length(m) Type name of JRC
FR-9
20MT
FR-9
30MT
COAX cable
Length(m)
HF-20D
30MT
1- 5
H-7AWRD0003
H-7AWRD0004
Type name of JRC
HF-20D (30MT)
1