JRC JMA-9133-SA Instruction Manual page 390

Hide thumbs Also See for JMA-9133-SA:
Table of Contents

Advertisement

>
JMA-9100 Instruction Manual
7.SETTINGS FOR SYSTEM OPERATION
7.3.4.2
Transmission Monitor Adjustment (MON Indicator Adjustment)
Adjust the circuit for monitoring the transmission performance of the radar
equipment.
The radar system is equipped with an interswitch.
For adjusting the performance unit, set the interswitch connection to
straight, i.e. No.1 scanner is connected to No.1 display unit as the Master.
Procedures
1)
Open the Serviceman Menu.
2)
Perform the following menu open procedure to open the
performance monitor Indicator Adjustment menu.
3)
Increase or decrease the adjustment value so that the
performance monitor level indicator will be adjusted to "8".
4)
Attach the INFORMATION LABEL provided with the performance
monitor to an appropriate position on the display unit.
Write the performance monitor bar value check date to the
5)
INFORMATION LABEL.
1. Adjust Menu
4. TXRX Adjustment
5. MON Indicator Adjustment
MON
Notice: During performance monitor adjustment, all acquisitions by the
target tracking function are released.
The released target acquisitions are not recovered.
7- 38
>
7.3 ADJUSTMENT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents