JRC JMA-9133-SA Instruction Manual page 445

Hide thumbs Also See for JMA-9133-SA:
Table of Contents

Advertisement

JMA-9100 Instruction Manual
Message
Class
Battery Dead
Warning
Battery Low
Warning
GPS (HDOP)
Warning The HDOP level is increased (Decrease in the GPS
MON Test
Warning
Scanner Rotating
Warning
i. ALR No.: Unique alarm number in ALR sentence and ACK sentence
Table9-8: List of Interswitch Alarms and Messages
Message
Class
Connection
INFO
Masked
ISW (Data)
Alarm
ISW Busy
INFO
ISW Complete
INFO
ISW Error
INFO
ISW Standby
INFO
ISW Straight
INFO
ISW Time Out
INFO
Master Range CHG INFO
Master Standby
INFO
Pattern CHG Failed INFO
TXRX Standby
INFO
Update ISW
INFO
Software
i. ALR No.: Unique alarm number in ALR sentence and ACK sentence
>
9.TROUBLE SHOOTING AND AFTER-SALES SERVICE
Table9-7: List of Conditions Messages
Description
The battery is dead.
battery is weakening.
accuracy.).
Performance monitor is active.
The scanner is rotating (When transmitter is standby
state.).
Description
Inhibition of control / connection is set.
No communication, data mismatched, or checksum error.
Access to the ISW menu was made during interswitching.
The switchover of the Interswitch ended normally.
The interswitch is disabled.
The Interswitch recovered normally.
The interswitch is forced to change the connection
into straight.
Failed in switching.
The range of the own display unit has changed due
to change in the range of the master display unit.
The master display unit does not transmit any
signals.
Connection change failed.
The scanner unit is in the standby mode.
Tried to enter new TXRX function, when interswitch
software used old version.
9- 5
>
9.1 FAULT FINDING
i
ALR No.
i
ALR No.
327
9