3.BASIC OPERATION
3.8.8.5
TEMP Graph Setting
• The TEMP Graph Setting menu will appear.
[1] TEMP Graph Display
• Determine whether to display the graph of the water-temperature data that has
been received on the radar display.
• One of two digital information areas is used to display data.
• When the water-temperature graph is displayed, the sizes of the target tracking
(TT)/AIS numeric data display areas are exclusively decreased.
• Left-click the
water-temperature graph display function is switched between On and Off.
[2] TEMP Graph Color
• Set the color for the water-temperature graph.
• There are eight selection items:
,
White
[3] TEMP Range
• When Color is selected for the display color for the water-temperature graph,
set the temperature range of each color.
[4] Time Range
• Set the time range for the water-temperature graph.
>
3.8 APPLIED OPERATIONS
button located at thelower righit of the display. The
Target
: The water-temperature graph is not displayed.
Off
: The water-temperature graph is displayed in digital information area 1.
Area1
Area2
: The water-temperature graph is displayed in digital information area 2.
,
,
Gray
Blue
10min
: The time range is set at 10 minutes.
: The time range is set at 15 minutes.
15min
30min
: The time range is set at 30 minutes.
60min
: The time range is set at 60 minutes.
12hour
: The time range is set at 12 hours.
3 -108
,
,
Green
Yellow
,
Pink
Red