8.3.4. /EDID
The node and its subnodes represent all information about EDID management. The node
contains basic methods in connection with EDID emulation such as Copy, Delete or
Emulate EDID. Subnodes refer to the type of the EDID as follows:
The node structure of Factory, User and Dynamic EDIDs contain the available EDIDs as
subnodes. The structure of these EDID subnodes is the same:
For detailed information about EDID memory see section
8.3.5. /MEDIA
MEDIA node contains the available layers on installed modules, such as VIDEO, AUDIO,
UART or IR module. Port and Crosspoint settings are structured in subnodes with methods
and properties in the nodes of the layers.
8.3.6. /SYS
The node has two subnodes: LOG and CORE.
/SYS/LOG
Last log events collected from last booting. The structure is the same as for
/MANAGEMENT/LOG.
/SYS/CORE
The node contains properties of MODEX frame; nevertheless its subnodes contain the
installed modules (B, C, D and E). Signal parameters are listed in the subnodes.
Page 68 / 90
F:
Factory EDIDs,
U:
User EDID,
D:
Dynamic EDID (The EDID of the monitor last attached to the receiver),
E:
Emulated EDID (List of assigned video ports).
Header:
Valid/Invalid (based on EDID header)
EDID data – in HEX format
Data:
True/False – (based on EDID data)
IsValid:
4.3
on page 23.
Section 8. Programmer's reference
Need help?
Do you have a question about the MODEX-OPTS-TX and is the answer not in the manual?
Questions and answers