Method
'Method' in the LW3 protocol is also a leaf. It cannot have a value, such as the properties,
but it can be invoked with a parameter with the help of a special 'CALL' command (see
section
Format: mX●/[nodeName]:[methodName]=[returnValue]
Legend:
Example:

8.1.2. Escaping

Property values and method parameters can contain characters that are used as control
characters in the protocol. They must be escaped. The escape character is the backslash
('\') and escaping means injecting a backslash before the character that should be escaped
(like in C language).
Control characters are the followings: \ { } # % ( ) \r \n \t
Example:
Original text:
Escaped text:
Page 60 / 90
8.2.5
on page 64).
A method cannot have child nodes or child methods. It is always a leaf.
A node can have any number of methods (may not have any).
A method is referenced with a colon (':') after the node.
Methods' name can contain the elements of the English alphabet, numbers and
underscore ('_') character.
By convention, methods are beginning with lowercase letter. In case of compound
words, the very first letter is lowercase, and the first letter of each other words are
capitalized (lowerCamelCase).
The parameter of the method can contain any readable ASCII character (control
characters have to be escaped, see section
The method always has a return 'state' if the method could be executed. The state
could be either 'OK' or 'FAILED'.
The method not necessarily has a return 'value'. If it does, it can contain additional
information, which is always specific for the current case (return value can specify
why the execution failed). Find details in section
When the method cannot be executed (e.g. the parameter list is illegal), there is
an error message (see section
m:
method
X can be:
'O':
when the execution of the method was successful,
'F':
when the execution of the method failed,
'm':
manual for the method (see section
'E':
error message for the method (see section
< mO●/node1/node12:method1
< mO●/MEDIA/IR/XP1:DefaultSwitch
< mO●/EDID:DeleteEdid
John●(Doe).●#3:●5%2=1●node1\node11
John●\(Doe\).●\#3:●5\%2=1●node1\\node11
8.1.2
on page 60).
8.2.5
8.1.3
on page 61).
8.2.9
Section 8. Programmer's reference
on page 64.
on page 66),
8.1.3
on page 61).

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MODEX-OPTS-TX and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Modex-opts-rxModex-optm-txModex-optm-rx

Table of Contents