4.6.2.3 BELT, DUPLEX, FRONT
1.
Open the MP TRAY ASSY.
2.
Remove the G-RING; 3 that secures the left PULLEY, DUPLEX, FRONT, and
pull out the PULLEY, DUPLEX, FRONT (left) from the GUIDE, DUPLEX,
OUTER.
Hitch the BELT, DUPLEX, FRONT to the left PULLEY,
DUPLEX, FRONT before attaching the left PULLEY, DUPLEX,
FRONT to the shaft of the GUIDE, DUPLEX, OUTER.
3.
Remove the E-RING, 3, L/Na that secures the right PULLEY, DUPLEX, FRONT,
pull the right PULLEY, DUPLEX, FRONT out of the GUIDE, DUPLEX,
OUTER, and remove the BELT, DUPLEX, FRONT.