EPSON AcuLaser C2600/2600
4.5.7.6 TRANSFER UNIT, Assy., ASP
REMOVAL
D1. Remove the Photoconductor unit.
D2. Remove the Fuser unit.
(p.237)
D3. Remove the COVER ASSY., FU.
C A U T I O N
When performing the following work, set the LEVER, TENSION to
transfer position, or Transfer belt release button may fall off when
removing the TRANSFER UNIT, Assy., ASP.
If the button mistakenly falls of, follow the procedure below to
assemble the parts.
D1. Attach the compression spring and the Transfer belt release button
to the shaft.
D2. Insert the LEVER, TENSION to the shaft.
D3. With the Transfer belt release button pressed against inside the
TRANSFER UNIT, Assy., ASP, rotate the LEVER TENSION to
the transfer position.
D4. Pull out the LEVER, TENSION from the shaft.
D4. Tuck the button and set the LEVER, TENSION to transfer position.
D5. Remove the LEVER, TENSION.
D6. Remove the 4 screws that secure the FRAME ASSY., FU to remove the FRAME
ASSY., FU.
C.P.POLYWAVEA,3x6,F/Zn: 2
C.B.S-TITE SCREW,3x8,F/Zn: 2
Disassembly and Assembly
(p.235)
(p.242)
(p.248)
Disassembling/Assembling the Main Unit
FRAME ASSY., FU
LEVER,
TENSION
D4-2
D4-1
Figure 4-76. Removal of TRANSFER UNIT, Assy., ASP 1
D7. Disconnect the 2 connectors from the Fuser cover open sensor.
Revision B
C.P.POLYWAVEA,3x6,F/Zn
D6-1
D6-1
C.B.S-TITE
SCREW,3x8,F/Zn
Caution
Compression
D3-1
Spring
D3-2
Transfer belt
release button
04005902
284