A6. While holding down the MOUNTING PLATE ASSY., PINION so as not to shift
its position, screw the MOUNTING PLATE ASSY., PINION together with the
SPUR GEAR,16, MPT.
C.C.SCREW,3x6,F/Uc: 1
A7. Slide the PAPER GUIDE, FRONT, MP and the PAPER GUIDE, REAR, MP,
ASSY. outward and then check the cursor position.
A8. Confirm that the position corresponds with the one checked in the "Removal"
procedure D2.
→
Matched
End of the work.
→
Unmatched
Go to procedure A9.
A9. Loosen the screw that secure the MOUNTING PLATE ASSY., PINION to slide it
from behind the LIFT PLATE, MP, and adjust the cursor position.
A10.Tighten the screw while holding down the MOUNTING PLATE ASSY., PINION
so as not to shift the cursor position.