EPSON AcuLaser C2600/2600
4.5.12.2 COMPRESSION SPRING, 10.58
1.
Pull the Standard lower paper cassette out of the printer.
2.
Press the tab on the right side of the TRAY, CASSETTE outward to pull the dowel
that secures the LIFT PLATE, MPC out of the hole, and lift up the right side of the
LIFT PLATE, MPC to release the dowel located at the left side of the LIFT
PLATE, MPC.
3.
Rotate the LIFT PLATE, MPC by 90 degrees upward, release the left tab of the
LIFT PLATE, MPC by sliding it toward right and then release its right tab to
remove the plate.
4.
Release the 2 COMPRESSION SPRNIG, 10.58s from the 2 tabs of the LIFT
PLATE, MPC, and remove the 2 COMPRESSION SPRING, 10.58s.
When attaching the COMPRESSION SPRING, 10.58, be careful
to follow the instructions below.
1.
Hitch one end with a smaller coil diameter to the 2 tabs of the
LIFT PLATE, MPC.
2.
Match the other end that has a larger diameter with a circularly-
pitted area of the TRAY, CASSETTE.
Disassembly and Assembly
LIFT PLATE, MPC
3-2
Reassembly
Disassembling/Assembling the Main Unit
3-1
3-3
4
4
COMPRESSION
SPRING, 10.58
2
TRAY, CASSETTE
Figure 4-131. Removal of COMPRESSION SPRING, 10.58
Revision B
2-1
2-2
2-3
2-4
04011401
340