EPSON AcuLaser C2600/2600
4.5.3.2 DETECTOR ASSY., GATE
1.
Open the MP TRAY ASSY.
C A U T I O N
1.
When performing the following work, pay attention not to damage
the ROLLER, GATE.
2.
Remove the screw that secures the GUIDE, GATE, RIGHT, ASSY. to remove the
GUIDE, GATE, RIGHT, ASSY.
C.C.P-TITE SCREW,3x8,F/Zn: 1
1.
Insert the 2 attachment shafts of the GUIDE, GATE, RIGHT,
ASSY. into the positioning holes.
2.
Match the notch of the GUIDE, GATE, RIGHT, ASSY. with the
salient position.
3.
Remove the 3 screws that secure the GUIDE, ASSY., FEED, LEFT.
C.C.P-TITE SCREW,3x8,F/Zn: 3
2.
When performing the following work, take care not to bend the
C A U T I O N
SHEET, CASSETTE.
4.
Slide the upper side of the GUIDE, ASSY., FEED, LEFT toward lower right to
release the 4 tabs, and remove the GUIDE, ASSY., FEED, LEFT.
3.
Insert the downside of the GUIDE, ASSY., FEED, LEFT into the
clearance between the ROLLER, FEED and the SHEET,
CASSETTE.
Disassembly and Assembly
GUIDE, ASSY.,
FEED, LEFT
3
Caution 2: SHEET, CASSETTE
Disassembling/Assembling the Main Unit
Reassembly
2
GUIDE, GATE,
RIGHT, ASSY.
2
3
3
4-2
4-2
4-2
4-1
Figure 4-45. Removal of DETECTOR ASSY., GATE 1
Revision B
Reassembly
1
4-2
04003301
254