Epson AcuLaser C2600 Service Manual page 173

A4 full color laser printer
Hide thumbs Also See for AcuLaser C2600:
Table of Contents

Advertisement

EPSON AcuLaser C2600/2600
E126: Abnormally low temperature 1
Error Occurrence/Error Detection Method
The temperature of the Heat Roller and the Pressure Roller do not reach the
specified temperature within a fixed time period after the heater is turned on.
Possible Parts Caused the Error
No.
Part Name
1
Fuser unit
2
POWER SUPPLY (230 V) / POWER SUPPLY (120 V)
3
BOARD ASSY., MAIN C585 MCU
Check Point
No.
1
Check if the NIP lever is used at the position for envelopes.
Check the Fuser Unit for the followings.
Check if paper is jammed at the Fuser.
2
Check the fuser roller for any scratch or foreign material.
Rotate the green knob on the backside of the fuser unit in order to check if
the spur gear 19 and heat roller turn smoothly.
3
Replace the [Fuser unit].
4
Replace the [POWER SUPPLY].
5
Replace the [BOARD ASSY., MAIN C585 MCU].
Troubleshooting
Reference
page 237
page 319
page 310
Check Point
Troubleshooting According to the Error Message
Diagram
BOARD ASSY.,
MAIN
C585 MCU
gry
gry
S24V
5
1
(N.C.)
4
2
/HR_ON
3
3
/HR_SUB
2
4
/HR_MAIN
1
5
plo
AC LIVE
1
(N.C.)
2
HR_LAMP
3
PR_LAMP
4
HARNESS, AC,
FUSER
1
2
3
(N.C.)
4
wht
Vcc_PS_EJ
6
A5
S.GND
7
A4
/PS_EJ
8
A3
TEMP_PR
9
A2
S.GND
10
A1
wht
/FUSE_CUT2
11
B7
/FUSER_SET
12
B6
P.GND
13
B5
TEMP_HR1
14
B4
S.GND
15
B3
TEMP_HR2
16
B2
S.GND
17
B1
HARNESS, MAIN
Revision B
POWER SUPPLY
Relay
Fuser Unit
Fuser HR Thermostat
Fuser HR Heater
1
Fuser PR Thermostat
2
Fuser PR Heater
3
(N.C.)
4
wht
A1
A2
A3
Fuser PR Thermistor
A4
A5
Fuser Sub Board
wht
wht
B1
3
Old and New detection fuse
B2
2
Detecting installed status
B3
1
B4
Fuser HR Thermistor
B5
Fuser HR Thermistors
B6
located at the one end
B7
03002001
173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aculaser 2600

Table of Contents