EPSON AcuLaser C2600/2600
6.
Remove the E-RING, 5, L/NA that secures the SHAFT, CAM from the inside, and
remove the BUSHING, 8.
7.
Remove the E-RING, 4, L/NA that secures the SHAFT, CAM from the outside,
and remove the BUSHING, 6.
8.
To remove CLUTCH, 2ND TRANSFER and the SHAFT, CAM, slide them
inward to pull the shaft of the SHAFT CAM out of the hole on the outside
FRAME ASSY., REAR, MP, and lift them to draw the shaft out of the hole on the
inside frame.
9.
Remove both the SHAFT, CAM and the SPACER, 30; B from the CLUTCH, 2ND
TRANSFER.
4.
Attach the SPACER, 30; B to the CLUTCH, 2ND TRANSFER
with the concave side of the spacer facing to the clutch. And then
insert the CLUTCH, 2ND TRANSFER into the SHAFT, CAM
paying attention to their shape of cross-section.
5.
Match the tab of the FRAME ASSY., REAR, MP and the groove
of the CLUTCH, 2ND TRANSFER so as not to rotate.
Disassembly and Assembly
SPACER, 30; B
CLUTCH,
2ND TRANSFER
E-RING, 5, L/NA
Disassembling/Assembling the Main Unit
8-3
8-1
8-2
SHAFT, CAM
9
9
6
BUSHING, 8
Figure 4-126. Removal of CLUTCH, 2ND TRANSFER 2
Revision B
Reassembly
4
BUSHING, 6
7
E-RING, 4, L/NA
Reassembly
5
04010901
335