Electronic Control Board Replacement Report - ALLIANCE AA9231 Service

Automatic washer
Table of Contents

Advertisement

Electronic Control Board Replacement Report

Installation Date: _____________________
Model No. __________________________
1. What was the complaint?
2. Mark the cause of the complaint in the appropriate box below:
Washer Control Failure
Failure in Diagnostic Cycle
Transformer:
Resistance not in 60 – 112 Ohm range between P4 and P1?
Hot Water Relay K4:
120 Volts not found between P7 and P1 in hot fill?
Cold Water Relay K5:
120 Volts not found between P8 and P1 in cold fill?
Main Motor Relay K3:
120 Volts not found between "Com" and P1 in agitation?
120 Volts not found between "Com" and P1 in spin?
Agitation Relay K1:
120 Volts not found between P2 and P1 in agitation?
120 Volts found between P2 and P1 in spin?
Spin Relay K2:
120 Volts not found between P3 and P1 during spin?
120 Volts found between P3 and P1 during agitation?
Additional Comments:
Both copies of this form must be completed and returned with the control board.
Warranty is void if control board is returned improperly packed or damaged.
32283
Section 8 Service Procedures Unique to the Electronic Control Model Washers
Date Failed: _______________________________________
Serial No.: _________________________________________
Service Company Identification No.: _____________________
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Form No. 8027R1
85