51. BELT (Pump)

NOTE: Adjustment must be made after motor has
been properly positioned. Refer to Paragraph 50.
a. Remove front panel. Refer to Paragraph 27.
b. Loosen the two front mounting screws, then
loosen the rear screw. Refer to Figure 46.
Pump
Belt
Figure 46
32283
Pump
Attaching
Screws
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
c. Shift front of pump mounting bracket to the
right or left to obtain proper belt tension. Proper
tension is when belt can be deflected
approximately 1/2 inch (12.7 mm) from its
normal position by applying moderate pressure
(1-1/2 pounds – .675 kg) to a point midway
between pulleys. Refer to Figure 47.
d. After belt tension is obtained, tighten the three
pump mounting bracket screws.