Idler Lever And Pulley - ALLIANCE AA9231 Service

Automatic washer
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
Helper
Spring
The round spring hook
must be hooked in
rear hole for proper
idler lever operation.

31. IDLER LEVER AND PULLEY

a. Remove motor and mounting bracket. Refer to
Paragraph 30, steps "a" through "e".
b. Remove nut, washer and bolt holding idler
lever and pulley to motor mounting bracket.
NOTE: Refer to Figure 20 for idler lever and pulley
assembly sequence.
c. Apply No. 03637 Lubricant to the area of idler
lever making contact with motor mounting
bracket.
32283
Wire harness must
be installed ahead
of spring.
Motor Mounting
Bracket
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
Ground Wire
(Green)
Ground
(If present)
Screw
(If present)
Figure 19
Section 5 Service Procedures
Positioning
Tab
WA100-SV
Motor
Attaching
Screws
Ground Wire to Base
(Discontinued starting
Serial No. 42P74967)
W003
29