35. CABINET TOP ASSEMBLY

a. Remove two screws from bottom edge of front
panel. Refer to Figure 16.
b. Pull bottom of panel away from washer until
hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
Refer to Figure 16.
c. Remove two cabinet top hold-down screws.
Refer to Figure 23.
d. If area or space permits, tape loading door
closed and lift cabinet top to a vertical position
by hinging it on the rear hold-down bracket.
NOTE: Cabinet top is self-supporting, however, a
small chain may be used for additional support.
Refer to Figure 24.
32
Door Switch
and Out-of-Balance
Switch Assembly
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
Wire Harness
Disconnect
Blocks
Starting Serial No. R1339650XG and
Continuing through R1566483YG
Figure 23
Chain
Cabinet Top
Hold-Down
Screw
Door Switch
and Out-of-Balance
Switch Assembly
Figure 24