Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
Pivot
Dome
Figure 41
Centering
Spring
Figure 42
56
Washer Base
Dome Recess
Notch
(5)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
f. Connect the hose(s) from the outer tub to the
pump and tighten hose clamp(s).
g. Reconnect idler spring to clip on motor
mounting bracket and helper spring into the
back hole in the mounting bracket. Refer to
Figure 43.
h. Place drive belt on motor pulley, reach around
right side of motor, starting with belt on right
side of large pulley, run belt onto large pulley.
i. Route the pressure hose as shown in Figure 26.
Then route pressure hose back up through hole
in cabinet top.
j. Reconnect the filler hose to the backflow
preventer. Refer to Figure 26.
NOTE: When reinstalling filler hose, white line on
hose must be aligned with center line of backflow
preventer. Refer to Figure 26. A 1/8 inch clearance
is necessary to prevent the hose from rubbing on the
flange of the tub cover. Refer to Figure 27. Loosen
hose clamp and move hose to obtain the proper
clearance. Hose clamp must be positioned as shown
in Figure 26 so it will not interfere with the cabinet
top.
k. Reinstall cabinet top.
l. Remove control hood, reconnect pressure hose
to pressure switch. Then reinstall control hood.
m. Reinstall washer front panel.
n. Reconnect washer power cord and open water
supply valves.
NOTE: Washer must be run through a complete
cycle to make sure it is operating properly.
W003
32283