To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.

14. WALL RECEPTACLE POLARITY CHECK

Refer to Figure 1.
NOTE: Have a qualified
electrician check
polarity of wall
receptacle. If a voltage
reading is measured
other than that
illustrated, the qualified
electrician should
correct the problem.
32283
Section 4
Grounding
Neutral
Side
Round
Grounding
Prong
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
Figure 1
L1
Ground
115 ± 12
VAC
115 ± 12
VAC
W003
Neutral
0
VAC
W011G
13