ALLIANCE AR105M_X_CONTROL Installation Operation & Maintenance

Cabinet hardmount
Table of Contents

Advertisement

Washer-Extractors
Cabinet Hardmount
Refer to Page 9 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
CAUTION: Read the instructions before using the machine.
(If this machine changes ownership, this manual must accompany machine.)
Part No. D1599ENR14
www.alliancelaundry.com
July 2021

Advertisement

Table of Contents
loading

Summary of Contents for ALLIANCE AR105M_X_CONTROL

  • Page 1 Washer-Extractors Cabinet Hardmount Refer to Page 9 for Model Identification Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must accompany machine.) Part No. D1599ENR14 www.alliancelaundry.com July 2021...
  • Page 3: Table Of Contents

    Input Voltage Requirements................50 © Copyright 2021, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.
  • Page 4 Every 6 Months.................... 74 Care of Stainless Steel................... 75 Disposal of Unit..................76 Disconnecting the Machine................76 Disposal of Unit....................76 China Restriction of hazardous substances (RoHS)....... 77 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 5: Safety Information

    Read all instructions before using the washer. vere personal injury or death. • Install the washer according to the INSTALLATION instruc- tions. Refer to the Earthing (grounding) instructions in the IN- © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 6 ALWAYS © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 7: Safety Decals

    1. Verify that all warning labels are present and legible, replace erty damage. as necessary. unique_2_Connect_42_note-1620386305525 2. Check door interlock before starting operation of the ma- chine: © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 8 Do not bypass any safety devices in the machine. WARNING Operating the machine with severe out-of-balance loads could result in personal injury and serious equipment damage. W728 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 9: Introduction

    LAE105T LAX520X AR280N_X_CON- PAN030X LAE105X LAY080T TROL_PLUS AR350_X_CONTROL PAN040T LAE135T LAY080X AR350_X_CONTROL_PLUS PAN040X LAE135X LAY105T AR520_X_CONTROL PAN055T LAE180T LAY105X AR520_X_CONTROL_PLUS PAN055X LAE180X LAY135T Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 10 RX280N_X_CON- LAU080X PAC280X TROL_PLUS TROL_PLUS MWCX30_X_CONTROL RX350_X_CONTROL LAU105T PAC332T MWCX30_X_CON- RX350_X_CONTROL_PLUS LAU105X PAC332X TROL_PLUS MWCX55_X_CONTROL RX520_X_CONTROL LAU135T PAC520T MWCX55_X_CON- RX520_X_CONTROL_PLUS LAU135X PAC520X TROL_PLUS Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 11 SAE135D NX180M_X_CONTROL NX105M_X_CONTROL PAY240T SAE240D NX180M_X_CON- TROL_PLUS NX105M_X_CON- PAY332X PAY520X NX240_X_CONTROL TROL_PLUS NX135_X_CONTROL NX135M_X_CONTROL NX135M_X_CON- NX240M_X_CONTROL TROL_PLUS NX240M_X_CON- NX280_X_CONTROL NX280M_X_CONTROL NX280M_X_CON- TROL_PLUS TROL_PLUS Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 12 UAM180I UAC240I UAU240I UAX240I UAH240I UAR240I UAM240I UAC280I UAU280I UAX280I UAH280I UAR280I UAM280I UAC332I UAU332I UAX332I UAH332I UAR332I UAM332I UAC520I UAU520I UAX520I UAH520I UAR520I UAM520I © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 13: Serial Plate Location

    520I000001DK was manufactured in May 2015. 2020 Manufacturing Date - Year Table 1 Year Serial Number Character 2009 2010 2011 2012 2013 2014 2015 Table 1  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 14 N or Q August P or S September R or U October T or W November V or Y December X or Z Table 2 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 15: Delivery Inspection

    Replacement Parts If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laun- dry Systems at +1 (920) 748-3950 for the name and address of the nearest authorized parts distributor.
  • Page 16: Specifications And Dimensions

    [kg](100G) Shipping 1147 [520] weight, lbs. [kg](150G) Shipping 320 [145] 408 [185] 441 [200] 739 [335] 783 [355] 849 [385] weight, lbs. [kg](200G) Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 17 0.74 [0.55] 0.74 [0.55] 1 [0.75] 1 [0.75] 1.48 [1.1] 1.5 [2.01] 5.36 [4] hp [kW] (100G) Motor Size, 2.95 [2.2] hp [kW] (150G) Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 18 Wash se- quence, dB (100 G) Wash se- quence, dB (150 G) Wash se- quence, dB (200 G) Extract se- quence, dB (100G) Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 19 133 [6.38] pressure lbs./ft [kN/m (150G) Static floor 90 [4.29] 91 [4.37] 96 [4.58] 112 [5.36] 107 [5.14] 108 [5.20] pressure lbs./ft [kN/m (200G) Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 20 ± 7.76] ± 8.49] ± 8.58] ± 9.70] ± 10.5] [kN/m (200G) Frequency of dynamic load, Hz (100G) Frequency of dynamic load, Hz (150G) Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 21: Machine Dimensions

    [°C] Machine Dimensions NOTE: Beginning January, 2018: 80 L (20 lb.), 105 L (25 lb.), and 135 L (30lb.) models have embossed side pan- els. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 22 22. Drain valve or recycle valve - 3 in. [76 mm] ( 80 lb. / 332 L and 120 lb. / 520 L Models only) 23. Drain valve - 3 in. [76 mm] Figure 2 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 23 24.61 [625] 26.42 [671] 26.41 [671] 8.58 [218] 8.58 [218] 8.58 [218] 8.58 [218] 8.58 [218] 8.58 [218] 9.76 [248] 8.78 [223] Table 3  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 24: Mounting Bolt Hole Locations

    5.47 [139] 6.06 [154] 8.68 [220.5] 8.68 [220.5] 8.68 [220.5] 2.26 [57.5] 2.26 [57.5] 2.26 [57.5] 1.97 [50] 1.97 [50] 1.97 [50] Table 4  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 25 10.69 [271.5] 1.97 [50] 1.97 [50] 1.97 [50] 1.97 [50] 1.97 [50] 35.04 [890] 35.04 [890] 35.04 [890] 41.73 [1060] 41.73 [1060] Table 5  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 26: Floor Mounting Layout

    41.71 [1059.5] 37.82 [960.5] 49.04 [1245.5] 3.23 [82] 3.23 [82] 3.23 [82] 3.23 [82] 3.23 [82] Table 5 Floor Mounting Layout Dimensional Clearances CZW110N Figure 5 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 27 20 [500] (minimum) Distance above 31.50 [800] 31.50 [800] 31.50 [800] 45.28 45.28 45.28 41.34 52.36 machine (mini- [1150] [1150] [1150] [1050] [1330] mum) Table 6 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 28: Installation

    The machine's side panel can be damaged. NOTE: Two self-adhesive rubber stop-blocks are supplied with the machine. They may be applied as paint protection when opening the door. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 29: Machine Installation

    11. Allow concrete to cure for at least one week before installa- size] for the perimeter reinforcing bar into the existing floor. tion of the machine. 5. Clean out debris from each reinforcing bar hole. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 30 Refer to Table 4 or Table 5 , Specification G 2.95 [75] 31.12 31.12 35.65 37.74 43.48 46.44 42.54 53.76 [790.5] [790.5] [905.5] [958.5] [1104.5] [1179.5] [1080.5] [1365.5] Table 8 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 31: Machine Installation On Floor Or Steel Base

    2. Washers; 60mm external diameter, 16.5mm internal diameter, 6mm thickness; supplied with the machine 3. Spacing washer 4. Anchor bolt 5. Washing machine 6. Concrete floor Figure 8 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 32 (80 x 80 mm). 3. Fit a washer and self-locking nut on the anchor bolt and tight- en with a torque wrench to 100Nm. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 33 18 kg/ 40 lb. / 180 L, 24 kg / 55 lb. / 240 L and 28 kg / 70 lb. / 280 L with 200 G Extraction; 35 kg / 80 lb. / 332 L and 52 kg / 120 lb. / 520 L CHM2474N_SVG 1. Washing machine 2. Spacing washers, as needed 3. Concrete floor Figure 11 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 34: Machine Grouting (North American Models Only)

    M16 during installation W945 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 35: Drain Connection

    Installation Drain Connection CHM2513N_SVG 1. Drain connection Figure 12 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 36: Drain Valve

    Avoid sharp bends which may prevent proper draining. The drainage pipe should be located over a floor drain, drainage channel. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 37 0.79 [20] 0.79 [20] 0.79 [20] D mini- 3.94 [100] 3.94 [100] 3.94 [100] 3.94 [100] 3.94 [100] 3.94 [100] 3.94 [100] 3.94 [100] Table 9 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 38 If the main drain pipe cannot be sufficiently ven- must have dimensions suitable for double the value of water flow. ted, install a vent per machine. Every time a machine is coupled © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 39 Drain Line Sizing / Minimum Drain ID, in. [mm] A - 1 Machine B - 2 Machines C - 3 Machines 3 [75] 4 [100] 5 [125] Table 11 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 40: Drain Pump, 7.5 Kg / 20 Lb. / 75 L Models Outside Of North America

    In order to achieve good draining, the hose must not bend at a sharp angle. Refer to Figure 15 . CHM2514N_SVG 1. Drain hose bend Figure 15 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 41: Water Connection Requirements

    © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 42 If additional hose lengths are needed or using hoses other than Figure 19 those supplied by manufacturer, flexible hoses with screen filters are required. Water type Water connection Table 12  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 43 Suitable air cushions (risers) should be installed in supply lines to prevent “hammering.” Alliance Laundry Systems, LLC ranges of front loading commer- cial clothes washing machines have solenoid valves at the inlets. Minimum and maximum working pressure 1 bar and 8 bar. The machines are supplied with approved inlet hoses.
  • Page 44: Connecting Hoses

    5. Turn water on and check for leaks. 6. If leaks are found, retighten the hose couplings. 7. Continue tightening and rechecking until no leaks are found. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 45: Water Reuse Connection (Optional)

    Water Reuse Specifications sewer must not be able to flow back into the reuse tank. Temperature range, °F [°C] 41 to 194 [5 to 90] Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 46: Electrical Installation Requirements

    © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 47: Residual Current Device (Rcd) - Models Outside Of North America

    5. Phase conductors 6. Protective conductor 7. Main switch inlet terminal switchboard 8. Neutral conductor Figure 25 IMPORTANT: Alliance Laundry Systems warranty does not cover components that fail as a result of improper input voltage. © Copyright, Alliance Laundry Systems LLC - Part No.
  • Page 48: Supply Cable

    1. Protection conductor 2. Phase conductor 3. Phase conductor 4. Phase conductor 5. Neutral conductor 6. Molded tube 7. Stripped length of conductors Figure 26 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 49: Machine Protective Earth Connection And Equipotential Bonding

    14 ). However, for the protection purposes, with the supply cable 5. W cross section of a min. 4 mm , select a larger conductor section, 6. V i.e., 6 mm 7. U Figure 27 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 50: Input Power Conditioning

    W810 IMPORTANT: All quick disconnects should comply with the specifications. DO NOT use fuses instead of circuit breakers. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 51: Connection Specifications

    Machine's Electrical Electrical Service Wire Connection Terminal Electrical Connection Terminal Block Neutral PE (Ground) Table 17 Electrical Connection Terminal Block CHM2496N_SVG Figure 29 CHM2499N_SVG Figure 31 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 52: Three-Phase Connections

    Connection Terminal Machine's Electrical Electrical Service Wire Connection Terminal PE (Ground) PE (Ground) Neutral Table 18 Table 19 Electrical Connection Terminal Block CHM2501N_SVG Figure 34 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 53: Phase Adder

    When a gravity drain is provided (no pump execution), the facto- ry setting for the drain valve is 60Hz for North American models and 50Hz for models outside of North America. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 54: Electrical Specifications - Models Outside Of North America

    L3, N) 12.6 (6) 17 (9) 380-415 50/60 3 (L1, L2, 11.7 (6) 16.2 (9) 440-480 50/60 3 (L1, L2, 13.5 (7) 15.5 (9) Table 20 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 55 3 (L1, L2, 0.65 12.6 (6) 17 (9) 12.6 21.3 (12) 440-480 50/60 3 (L1, L2, 0.65 12.3 (7) 15.7 (9) 12.6 20 (12) Table 21 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 56 12.9 (6) 17.2 (9) 12.8 21.5 (12) 14.6 13.8 (22.5) 32 440-480 50/60 3 (L1, L2, 0.85 12.2 (7) 15.9 (9) 12.8 20 (12) Table 22 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 57 Standard Electric Heat 200-240 50/60 2 (L1, L2, or L1, N) 200-240 50/60 3 (L1, L2, 12.9 36.2 (12) 18.9 53 (18) Table 24  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 58 31 (18) 380-415 50/60 3 (L1, L2, 12.9 20.7 (12) 18.9 29.7 (18) 440-480 50/60 3 (L1, L2, 12.9 19.4 (12) 18.9 27.4 (18) Table 24 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 59 2 (L1, L2, or L1, N) 200-240 50/60 3 (L1, L2, 53 (18) 380-415 50/60 4 (L1, L2, 31.7 (18) L3, N) Table 26  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 60 (21.9) 380-415 50/60 3 (L1, L2, 19.3 30 (18) 23.2 38 (21.9) 440-480 50/60 3 (L1, L2, 19.3 29 (18) 23.2 35 (21.9) Table 27 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 61 (21.9) 380-415 50/60 3 (L1, L2, 19.3 30 (18) 23.2 38 (21.9) 440-480 50/60 3 (L1, L2, 19.3 29 (18) 23.2 35 (21.9) Table 28 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 62 200-240 50/60 2 (L1, L2 or L1, N) 200-240 50/60 3 (L1, L2, 16.5 (40.6) 380-415 50/60 3 (L1, L2, 62.9 (40.6) Table 30  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 63 Installation Standard Electric Heat 440-480 50/60 3 (L1, L2, 81.5 (40.6) Table 30 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 64: Electrical Specifications - North American Models

    Full Load Breaker Code cy (Hz) Phase Wire Amps (A) CSA (A) X and Z 208-240 2 (L1, L2 or 14 (2.5) L1, N) Table 34 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 65 (Hz) Phase Wire Amps (A) CSA (A) 208-240 3 (L1, L2, L3) 16 14 (2.5) 440-480 3 (L1, L2, L3) 9.6 14 (2.5) Table 38 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 66: Steam Requirements (Steam Heat Option Only)

    Check at regular intervals for chemical leaks. W363 Supply Dispensing Number of external liquid supply connections Table 40  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 67: Connection Of External Liquid Supplies

    NOTE: Do not attempt to make chemical injection sup- ply pump electrical connections to points other than those provided specifically for that purpose by the fac- tory. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 68: Electrical Connection Of External Liquid Soap Supply System

    Loops do not prevent drips if these instructions are not followed. Failure to fol- low these instructions could damage the machine and void the © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 69 Figure 39 shows a typical chemical injection supply system. Chemical Injection Supply System 1. Injection Point 2. Chemical Dispenser Pump Outlet 3. PVC Pipe Figure 39 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 70: Operation

    The safety system serves as protection maining. against violent handling and damage to the door 9. Press the START keypad. lock while the machine is operating. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 71 Before you open the door, make sure that the drum is completely still and all water has drained. W903 © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 72: Before Washing

    If a short term power cut occurs, this module does not affect the operation of the machine. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 73: Maintenance

    IMPORTANT: Do not use abrasive cleaners. 1. Check door interlock before starting operation: a. Attempt to start the machine with the door open. The ma- chine should not start. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 74: Quarterly

    .5mm thick washer to the fixed lower hinge pin. The washer was included when the machine was delivered, but can be ordered from Alliance Laundry Systems under part number 571642. b. Try to turn the door in a clockwise or counterclockwise rotation.
  • Page 75: Care Of Stainless Steel

    Door handle central bolt 6.49 [8.8] Locate the pump and tubing below the machine’s injection point to prevent siphoning of chemicals into the machine. Table 42  continues... © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 76: Disposal Of Unit

    For more detailed information about recycling of this product, please contact the local city office, household waste disposal service, or the source from which the product was purchased. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...
  • Page 77: China Restriction Of Hazardous Substances (Rohs)

    NOTE: The referenced Environmental Protection Use Period Marking was determined according to normal oper- ating use conditions of the product such as temperature and humidity. This product under normal use, durable years of environmental protection is 15 years. © Copyright, Alliance Laundry Systems LLC - Part No. D1599ENR14 DO NOT COPY or TRANSMIT...

This manual is also suitable for:

Ar105m_x_control plusAr105n_x_controlAr105n_x_control_plusAr135m_x_controlAr135m_x_control_plusAr135n_x_control ... Show all

Table of Contents