Mixing Valve Assembly; Washtub And Lint Filter - ALLIANCE AA9231 Service

Automatic washer
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
Pressure
Hose
Mixing Valve
Attaching
Screw
Wire Harness
Clip
Through Serial No. R1339649XG

37. MIXING VALVE ASSEMBLY

NOTE: Starting with Serial No. R1339650XG and
continuing through R1566483YG, a guard was
added to the mixing valve area. The guard must be
removed before the mixing valve can be serviced.
a. Hinge cabinet top or remove. Refer to
Paragraph 35.
b. Remove screw holding mixing valve to
mounting bracket at rear of washer cabinet.
Refer to Figure 26.
NOTE: When installing mixing valve, tab on
bottom flange must be placed in positioning hole in
mounting bracket.
c. Pull mixing valve out toward front of washer
far enough to permit disconnecting water inlet
hoses from mixing valve. Refer to Figure 26.
d. Disconnect wires from mixing valve solenoids.
32283
Water Inlet
Hose
Backflow
Preventer
Center
Line
White
Line
Hose
Clamp
Filler
Hose
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
Wire Harness
Enclosure
Mixing Valve
Attaching
Screw
Hose
Clamp
Starting Serial No. R1339650XG and
Continuing through R1566483YG
Figure 26
NOTE: Refer to appropriate wiring diagram when
rewiring solenoids.

38. WASHTUB AND LINT FILTER

a. Remove agitator. Refer to Paragraph 25.
b. Hinge cabinet top or remove. Refer to
Paragraph 35.
c. Disconnect filler hose from backflow
preventer. Refer to Figure 26.
NOTE: When installing filler hose, white line on
hose must be aligned with center line of backflow
preventer. Refer to Figure 26. A 1/8 inch clearance
is necessary to prevent the hose from rubbing on the
flange of the tub cover. Refer to Figure 27. Loosen
hose clamp and move hose to obtain the proper
clearance.
Section 5 Service Procedures
Water Inlet
Hose
Backflow
Preventer
Center
Line
White
Line
Filler
Hose
Pressure
Hose
W003
35

Advertisement

Table of Contents
loading

Table of Contents