System Event
Null Trigger (used for direct control)
Fire Alarm
Police Alarm
Auxiliary Alarm
Any Audible Alarm
Silent Alarm (sensor groups 2, 3, and duress)
Any Audible or Silent Alarm
HOM Group 27, 28, 32 in Alarm
Major Trouble (phone or receiver failure)
Arming to STAY or AWAY
Arming to AWAY
AVM is Interactive (audio session in progress)
Fail-to-Communicate (panel can't call CS or pager) When the fail-to-communicate output is activated.
AVM Trip (edge)
Keychain Touchpad Star Button-Press
Smoke Power (for resetting 4-wire smoke detectors) Deactivated when hardwire smoke detectors need to be reset. 015
Exterior Siren
Interior Siren
AVM Trip (pulse)
State of System Status
Tamper Condition
Closing Report Sent
Group XX in Alarm
Sensor XX in Alarm
Sensor XX Open
87
Table B3: System Event Trigger Numbers
Activated only by schedule or direct command.
When Fire sirens are started.
When Police sirens are started.
When Auxiliary sirens are started.
When any of the above sirens are started.
When a group 2 or 3 sensor goes into alarm or when a duress
alarm is activated (does not include groups 25, 27, 28, or 32).
When any alarm is started (does not include groups 25, 27, 28,
or 32).
When a sensor in group 27, 28, or 32 goes into alarm.
When a receiver failure (S94) or a phone failure (S96) occurs. 008
When the panel is armed to level 2 or 3.
When the panel is armed to level 3.
When the central station operator begins listening or talking to
the premises.
When an AVM alarm occurs, output is activated momentarily.
When the star button on a keychain touchpad is pressed.
Activated for police or fire alarms.
Activation follows all system noises
When an AVM alarm occurs, output is deactivated for 10 ms
Follows the state of system status (ready or trouble).
When any tamper is tripped
When a closing report has been successfully transmitted to the
central station.
When any sensor in group XX goes into alarm
When sensor number XX goes into alarm
When sensor number XX is opened
Table B4: Sensor Number Event Trigger Numbers
Sensor Number
Sensor 01
in alarm
Sensor 02
in alarm
Sensor 03
in alarm
Sensor 04
in alarm
Sensor 05
in alarm
Sensor 06
in alarm
Sensor 07
in alarm
Sensor 08
in alarm
Sensor 09
in alarm
Sensor 10
in alarm
Description
State
Trigger No.
State
129
open
130
open
131
open
132
open
133
open
134
open
135
open
136
open
137
open
138
open
Trigger No.
000
001
002
003
004
005
006
007
009
010
011
012
013
014
016
017
018
019
020
021
Table B4
Table B4
Table B4
Trigger No.
257
258
259
260
261
262
263
264
265
266
Concord