Audio Verify (0900)
This setting determines whether or not the
system can be accessed by phone for alarm
verification.
Audio Mode (0901)
This setting determines how the audio verification module operates. Choose one
of the following:
•
(1) Instant—Allows the central station operator instant access for an audio
session by entering the AVM code or by pressing * (if an AVM access code
is not programmed) upon completion of panel alarm report (also see
).
ACCESS TIMEOUT
•
(2) Callback—Allows the central station operator to contact persons on the
premises after one ring and verify the alarm report. Operator must press *
or enter the AVM access code within 20 seconds after ring. The panel does
not report any alarms during the AVM session, except for fire alarms.
•
(3) Callback Silent—Same as Callback, except premises phones do not
ring.
Fire Shutdown (0902)
This setting determines whether system sirens turn
off during a fire alarm audio session.
Silent Talkback (0903)
This setting determines whether the central station
operator can speak to persons on the premises (on)
or only listen (off) during a silent or duress alarm
audio session.
Access Timeout (0904)
If the Audio Mode is set to "Instant," then this set-
ting determines how much time (30–300s, in 2-sec-
ond increments) the central station operator has to
enter the AVM access code after the panel is
accessed for an audio session.
Concord
¾
To turn Audio Verification off or on:
1.
With the display showing
.
PARTITION 1
2.
Press # again and the display shows
3.
Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the
display shows the new setting.
¾
To turn Fire Shutdown off or on:
1.
With the display showing
the display shows
2.
Press 1 (off) or 2 (on). The display flashes the entered setting. Press
# and the display shows the new setting.
¾
To turn Silent Talkback off or on:
1.
With the display showing
the display shows
2.
1 (off) or 2 (on). The display flashes the entered setting. Press #
Press
and the display shows the new setting.
¾
To change the Access Timeout:
1.
With the display showing
the display shows
2.
Enter the desired time. The display flashes the entered setting. Press
and the display shows the new setting.
Audio Verification-Partition 1(Default = off)
, press #. The display shows
AUDIO VERIFICATION
AUDIO VERIFY OFF/ON
Audio Verification-Partition 1(Default = 1)
¾
To set Audio Mode:
1.
With the display showing
, press A or B until the display
OFF/ON
shows
AUDIO MODE nn
2.
Enter the desired mode number (1–3). The
display flashes the entered setting. Press
and the display shows the new setting.
Audio Verification-Partition 1(Default = off)
AUDIO VERIFY OFF/ON
FIRE SHUTDOWN OFF/ON
Audio Verification-Partition 1(Default = off)
AUDIO VERIFY OFF/ON
SILENT TALKBACK OFF/ON
Audio Verification-Partition 1(Default = 90 sec.)
AUDIO VERIFY OFF/ON
ACCESS TIMEOUT nn SECS
(current setting).
AUDIO VERIFY
(current setting).
#
, press A or B until
(current setting).
, press A or B until
(current setting).
, press A or B until
(current setting).
#
52