Note
For UL 1635 installations,
Entry Delay plus Dialer
Abort Delay must not
exceed 60 seconds.
3
The following table describes non-programmable (hard coded) system operation as required to
meet ANSI-SIA CP-01 and is provided only for your reference.
Function
Disarm During Entry Delay
Cancel Alarm
Abort Annunciation
Cancel Report Annunciation
Commercial Burglary Alarm System Unit (Grade C UL 1610)
Basic system using Control Panel 60-801-01 plus:
•
Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/Window
Sensor (60-499)
•
SAW PIR Sensor (60-639-95R), Crystal PIR Sensor (60-703-95R), or DS924i PIR Sensor
(60-511-01-95)
•
Immediate Beeps set to on
•
UL 98 Options set to on
•
Receiver Failure set to on (if wireless devices are used)
•
RF TX Timeout set to 4 hours
•
24-Hour Tamper set to on
•
System Tamper set to on
•
Auto Phone Test set to on
•
Phone Test Freq. set to 1
•
Next Phone Test set to 1
•
Siren Verify set to on
•
AC Failure set to on
•
Exit Delay set to 120 seconds or less
•
Quick Exit set to off
•
Two Trip Error set to off
•
Alarm Verify set to off
•
Disable Trouble Beeps set to off
•
Phone Number must be programmed
•
High Level Rpts set to on
•
Low Level Rpts set to on
•
Comm. Failure set to on
•
Extended Delay set to off
•
Sleep Time set to off
•
Siren Timeout set to 4 minutes or more
UL 1610 24-Hour Backup
•
Same as UL 1023 & 985
UL 1635 Digital Alarm Communicator System
Same as UL 1023, 985 & 1610 plus:
•
AC Failure set to on
•
Phone Number must be programmed
•
Low CPU Battery set to on
•
Next Phone Test set to 1
•
Phone Test Freq. set to 1
•
High Level Rpts set to on
•
Low Level Rpts set to on
•
Comm. Failure set to on
•
RF Tx Timeout set to 4 hours