AC Failure (06010)
When this setting is on, the panel reports to the central station 15
minutes after AC power to the panel is lost.
Note
For UL Listed installations, AC Failure must be set to on.
Receiver Failure (06011)
When this setting is on, the panel reports a receiver failure under the
following conditions:
•
No wireless sensor signals have been received for two hours or
•
The receiver is being jammed with a constant signal.
Note
For UL Listed installations using wireless devices, Receiver Failure must
be set to on.
RF Low Bat Rpt (06012)
This setting determines whether the panel sends daily or weekly
low battery reports to the central monitoring station when a wireless
device is reporting a low battery condition to the panel.
RF Supv Report (06013)
This setting determines whether the panel sends daily or weekly
reports to the central monitoring station when the panel detects a
supervisory condition in a wireless device.
Swinger Limit (06014)
This setting determines the maximum number of times (1–2) a sensor or zone can go into
alarm (during a single arming period) before the panel automatically bypasses that sensor
or zone. This feature only applies to sensors or zones in groups 00–20, 29, 34, or 35.
When set to 1, the panel automatically bypasses a sensor or zone after it causes an alarm.
When set to 2, the panel waits until a sensor or zone has caused a second alarm (during the
same arming period) before bypassing it. At any setting, the automatic bypass is logged
into the event buffer.
A bypassed sensor or zone will be cleared (automatically unbypassed) if the system
receives no further activations from that sensor or zone over the next 48–50 hours.
Changing the arming level also clears all automatically bypassed sensors and zones and
resets the Swinger Limit count on all sensors and zones.
45
Reporting-Global (Default = off)
¾
To turn AC Failure reports off or on:
1.
With the display showing
setting), press 1 (off) or 2 (on). The display flashes
the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn Receiver Failure reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The dis-
ON
play flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = weekly)
¾
To set RF Low Battery Report to daily or weekly:
1.
With the display showing
(current setting), press 1 (daily) or 2
WEEKLY
(weekly). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = weekly)
¾
To set RF Supv Report to daily or weekly:
1.
With the display showing
(current setting), press 1 (daily) or 2
WEEKLY
(weekly). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = 1)
¾
1.
2.
/
(current
AC FAILURE OFF
ON
RECEIVER FAILURE OFF/
RF LOW BAT RPT DAILY/
RF SUPV REPORT DAILY/
To set the Swinger Limit:
With the display showing
(current
SWINGER LIMIT n
setting), press the desired
number (1–2). The display
flashes the entered setting.
Press # and the display
shows the new setting.