Phone Number (pager 1: 0130, pager 2: 0140, pager 3:
0150, pager 4: 0160, pager 5: 0170)
This setting is used for programming a phone number that communicates
to a pager. Phone numbers can be 1 to 24 digits long and include pauses,
a skylink number, and 7-digit PIN number.
Note
Call-waiting services should be disabled to prevent interrupting panel commu-
nication to the pager(s). To program a dialing prefix that disables call-waiting,
see the Call Wait Cancel setting under the menu
To enter pauses, press C.
To enter *, press and hold 7 for about two seconds.
To enter #, press and hold 9 for about two seconds.
High Level Rpts (pager 1: 0131, pager 2: 0141, pager 3:
0151, pager 4: 0161, pager 5: 0171)
This setting determines whether the following alarm conditions report to a
pager:
•
Fire, Police, Auxiliary, and Duress alarms
•
No Activity
•
Receiver Failure (or jam)
•
Tamper conditions, including Zone Tampers and System Tamper (40
incorrect key presses or touchpad supervisory)
•
Entering or exiting Sensor Test mode
•
Phone Test
Low Level Rpts (pager 1: 0132, pager 2: 0142, pager 3:
0152, pager 4: 0162, pager 5: 0172)
This setting determines whether the following non-alarm conditions report
to a pager:
•
Force Armed
•
Hardwire Zone Trouble (open or short)
•
Supervisory (wireless devices)
•
Low Battery (wireless devices)
•
Phone Test
•
Other non-alarm related conditions
Exception Rpts (pager 1: 0133, pager 2: 0143, pager 3:
0153, pager 4: 0163, pager 5: 0173)
This setting determines whether the panel reports to a pager if the sys-
tem is not armed or disarmed at the specified schedule times, if open/
close reports are turned on.
33
PHONE OPTIONS—GLOBAL
.
Phones-Pager Phone 1-5 (Default = none)
¾
To program a Pager Phone Number:
1.
With the display showing
(or current number), enter the desired pager
phone number. The display flashes the entered
number.
2.
Press # and the display shows the new setting.
¾
To delete a Pager Phone Number:
1.
With the display showing
(current number), press D. The display shows
.
PHONE NUMBER _
Phones-Pager Phone 1-5 (Default = on)
¾
To turn High-Level Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
Phones-Pager Phone 1-5 (Default = off)
¾
To turn Low-Level Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
Phones-Pager Phone 1-5 (Default = off)
¾
To turn Exception Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
PHONE NUMBER _
PHONE NUMBER
HIGH LEVEL RPTS
LOW LEVEL RPTS
EXCEPTION RPTS
Concord
Need help?
Do you have a question about the Concord Security System and is the answer not in the manual?
Questions and answers