Star Is No Delay (partiton 1: 0514, partition 2: 0524)
This setting determines whether the keychain touchpad star button
controls an output (off) or the No Delay feature (on).
24-Hour Tamper (06000)
When this setting is on, the panel sounds sirens and reports a tamper
alarm (even when the system is disarmed), when wireless sensor
tamper switches are activated.
Note
For commercial UL Listed installations (UL 1610) the 24-Hour Tamper
must be set to on.
Buffer Control (06001)
When this setting is on, only arming level changes are logged in the
buffer (memory) of the panel. When this setting is off, all system
events are logged in the buffer.
Back In Service (06002)
When this setting is on, the panel reports to the central station when
AC and backup battery power are restored (after an extended power
outage).
Bypass Reports (06003)
When this setting is on, the panel reports to the central station
whenever sensors or zones are bypassed.
Low CPU Battery (06004)
When this setting is on, the panel reports a low panel battery to the
central station before shutting down.
Note
For UL 1635 listed installations, the Low CPU Battery feature must be
set to on.
43

Reporting Menu

The
menu lets you set up which system events are reported to the central monitoring
REPORTING
station. The following describes how to program the reporting settings that appear under
Touchpad Options-Partitions 1-2 (Default = off)
¾
To change the keychain Star Is No Delay setting:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn 24-Hour Tamper off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn Buffer Control off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = on)
¾
To turn Back In Service reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn Bypass Reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = on)
¾
To turn Low CPU Battery reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The dis-
ON
play flashes the entered setting.
2.
Press # and the display shows the new setting.
STAR IS NO DELAY OFF/ON
GLOBAL.
24 HOUR TAMPER OFF/ON
BUFFER CONTROL OFF/ON
BACK IN SERVICE OFF/ON
BYPASS REPORTS OFF/ON
LOW CPU BATTERY OFF/
Concord

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Concord Security System and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

60-792-01-95r60-734-0160-801-01

Table of Contents

Save PDF