DTMF Dialing (02004)
This setting determines whether the panel uses DTMF tones (on) or
pulse (off) for dialing programmed phone numbers.
Dialer Abort (02005)
This setting determines whether or not the user can stop a panel before it
sends a false alarm to the central station.
Note
Fire alarm reports to the central station cannot be aborted.
When this feature is on, alarm reports from sensors in groups 00–20, 34,
and 35 can be aborted. To abort the dialing attempt, the user must enter 1 +
user code within the Dialer Abort Delay time setting (defaulted to 30 sec).
Cancel and restoral reports from these sensor groups are aborted at the
same time. The following reports can also be aborted.
•
System Alarm Tamper/Cancel
•
No Activity Alarm/Cancel
•
Touchpad Police and Auxiliary Panic/Cancel
•
Recent Closing and Two Trip Error
Dialer Abort Delay (02006)
This setting determines how much time the user has to abort a panel
report.
Note
For UL Listed systems, the combined time for the Entry Delay (0310/0320)
and Dialer Abort Delay must not exceed 60 seconds.
Cancel Message (02007)
This setting determines whether or not the panel displays a cancel mes-
sage after the user disarms the system to clear an alarm condition.
Pager Delay (02008)
This setting determines how long a report is delayed to a pager, after the
panel dials the pager number.
Note
The Pager Delay time should not be set below 5 seconds, unless absolutely
necessary.
Concord
Phone Options-Global (Default = on)
¾
To turn DTMF Dialing off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The
ON
display flashes the entered setting.
2.
Press # and the display shows the new setting.
Phone Options-Global (Default = on)
¾
To turn Dialer Abort off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new set-
ting.
Phone Options-Global (Default = 30 sec.)
¾
To change the Dial Abort Delay:
1.
With the display showing
(current setting), enter the desired time
SECS
(15–120s). The display flashes the entered set-
ting.
2.
Press # and the display shows the new setting.
Phone Options-Global (Default = on)
¾
To turn Cancel Message off or on:
1.
With the display showing
(current setting), press 1 (off) or 2
OFF/ON
(on). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Phone Options-Global (Default = 15 sec.)
¾
To set the Pager Delay time:
1.
With the display showing
(current setting), enter a delay time (0–30).
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
DTMF DIALING OFF/
DIALER ABORT
DIAL ABORT DELAY nn
CANCEL MESSAGE
PAGER DELAY nn SECS
36
Need help?
Do you have a question about the Concord Security System and is the answer not in the manual?