Program Report (06015)
When this setting is on, the panel sends a report to the central sta-
tion when someone enters or exits installer programming.
Opening Reports (partition 1: 06100, partition 2: 06200)
When this setting is on, the panel sends an opening report to the central
station after disarming the system.
Note
To use this feature, the Open/Close Reports settings under the
menu must be turned on for the specific CS Phone or Pager number.
Closing Reports (partition 1: 06101, partition 2: 06201)
When this setting is on, the panel sends a closing report to the central
station after arming the system.
Note
To use this feature, the Open/Close Reports settings under the
menu must be turned on for the specific CS Phone or Pager number.
Recent Closings (partition 1: 06102, partition 2: 06202)
When this setting is on, the panel sends a recent closing report to the
central station if an alarm occurs within two minutes after the exit
delay time expires. Such a report is used to identify a possible exit
fault.
No Activity (partition 1: 06103, partition 2: 06203)
When this setting is on, the panel sends a no activity report to the cen-
tral station when the activity timeout expires (see
EOUT
).
Duress Option (partition 1: 06104, partition 2: 06204)
(Default = off) When this setting is on, the system can be controlled
using a programmed duress code (see
).
CODE
Note
For UL Listed installations, Duress Option must be set to off.
Do not use a duress code unless it is absolutely necessary. Using duress
codes often results in false alarms due to code entry errors. If a duress
code is absolutely necessary, use it with the audio verification module
to reduce false alarms and accidental dispatches.
Concord
The following sections describe the settings that appear under
TIMERS—ACTIVITY TIM-
SECURITY—PARTITION N—DURESS
¾
To turn Program Report on or off:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The
OFF
display flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Partition 1-2 (Default = off)
¾
To turn Opening Reports off or on:
1.
With the display showing
OFF/ON
The display flashes the entered setting.
PHONES
2.
Press # and the display shows the new setting.
Reporting-Partition 1-2 (Default = off)
¾
To turn Closing Reports off or on:
1.
With the display showing
OFF/ON
The display flashes the entered setting.
PHONES
2.
Press # and the display shows the new setting.
Reporting-Partition 1-2 (Default = on)
¾
To turn Recent Closings off or on:
1.
With the display showing
OFF/ON
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Partition 1-2 (Default = off)
¾
To turn No Activity reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Partition 1-2 (Default = off)
¾
To turn Duress Option off or on:
1.
With the display showing
rent setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
PROGRAM REPORT ON/
REPORTING—PARTITION 1-2
OPENING REPORTS
(current setting), press 1 (off) or 2 (on).
CLOSING REPORTS
(current setting), press 1 (off) or 2 (on).
RECENT CLOSINGS
(current setting), press 1 (off) or 2 (on).
NO ACTIVITY OFF/ON
DURESS OFF/ON
.